[Veritas-bu] Catalog tape bad
2004-02-25 13:03:17
It needs to be in the Netbackup pool.
~Kate
-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu] On Behalf Of Dan
Logcher
Sent: Wednesday, February 25, 2004 12:57 PM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: Re: [Veritas-bu] Catalog tape bad
David Chapa wrote:
> You can change that from the GUI or the command line using bpsyncinfo
>
>
>
> Ex. bpsyncinfo ?id[1|2] mediaid ?d[1|2] densitystr
I've done the GUI. Just change the VOLSER and make sure
the new tape is in the None Pool. It wouldn't work with
the tape in the scratch pool for NB 3.4.
--
Dan
_______________________________________________
Veritas-bu maillist - Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
This e-mail may contain confidential or privileged information. If you
think you have received this e-mail in error, please advise the sender by
reply e-mail and then delete this e-mail immediately. Thank you. Aetna
|
|
|