Veritas-bu

[Veritas-bu] Upgrading to 4.5 from 3.4 -- any gotchas?

2003-08-27 10:26:16
Subject: [Veritas-bu] Upgrading to 4.5 from 3.4 -- any gotchas?
From: kevin.v.vapiwala AT citigroup DOT com (Vapiwala, Kevin V [IT])
Date: Wed, 27 Aug 2003 10:26:16 -0400
my advice

I would save a copy of the following:


drive configuration output from tpconfig
sgscan output
copy of the auth.conf file for java
copy of all the license keys

in the past we've had to re-do the drive configuration when upgrading a
solaris master from 3.4 to 4.5



-----Original Message-----
From: James Adams [mailto:jsadams AT compuserve DOT com]
Sent: Wednesday, August 27, 2003 8:12 AM
To: Jack L. Forester
Cc: nbu-list
Subject: Re: [Veritas-bu] Upgrading to 4.5 from 3.4 -- any gotchas?


Just did that in June.  Had no problems with the Sun master or clients. 
The Windows and Novell server/clients were somewhat problematic - patch
levels, wrong iteration of IE, upgrade installer.  You should be fine.
_______________________________________________
Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu