try tpconfig -l?
What does it say??
-Murali
> -----Original Message-----
> From: veritaslist AT mailmgr DOT com [mailto:veritaslist AT mailmgr DOT com]
> Sent: Thursday, August 28, 2003 12:48 PM
> To: veritas-bu AT mailman.eng.auburn DOT edu
> Subject: [Veritas-bu] Tape drives keep going down upon use on
> Solaris 8
> master server after upgrade
>
>
> Hi, last week, I configured my drives from the OS (solaris 8)
> through NBU (datacenter) and everything was happy. Yesterday,
> I installed the most recent 8_Recommended patch set.
> Everything looked OK and I left it. Today, I notice that the
> drives go down every time I try to use them through NBU. When
> I kick off a job, I get this error:
> Aug 28 14:41:29 backup1.dmc.org avrd[1912]: Fatal open error
> on IBMULTRIUM-TD13
> (device 1, /dev/rmt/5cbn), errno = 6 (No such device or
> address), DOWN'ing it
>
> If I drop to the OS level, the drives are there just as they
> should be (/dev/rmt entries pointing to /devices/... entries.
> I have also noticed this:
> # mt -f /dev/rmt/0 status
> /dev/rmt/0: No such device or address
>
> But, if I do a reconfig reboot the drives are put back in
> their normal place, and n sgscan sees the drives where I
> would expect it to.
>
> This problems was occuring beforehand, but I did also upgrade
> from NBU datacenter 4.5GA to 4.5 MP5 today.
>
> Any thoughts? I am stuck and our backups are dead in the water.