We have opened the doors on our L700 libraries while jobs were running with=
 no ill-effects. Granted we're not that busy all the time. Basically the on=
ly thing you might lose is a couple of robotic mounts which NBU may make yo=
u mount manually because the robot was unavailable while the door was open.=
 I can't say this for sure because it's never happened to us ... but it was=
 something we thought about when we opened the door the 1st time. Good luck=
=2E

Dennis

Dennis F. Dwyer
Manager, Systems Software
Tampa Electric Company

(813) 225-5181  - Voice
(813) 275-3599  - FAX

Visit our corporate website at www.tecoenergy.com

The Master Chief Says: "Time is not a test of the truth"
Translation: Just because you've always done it that way, doesn't make it r=
ight

>>> <Karl.Rossing AT Federated DOT CA> 08/19/2003 2:22:52 PM >>>

I have opened the door on my SUN L400(Exabyte 220 library) with 2 drives an=
d 4 trays while netbackup was running to inject new media.=20

I didn't run into problems. I just made sure that the arm wasn't picking ta=
pes.=20

For the L700 it might be different.




Karl-Fr=E9d=E9ric R=F6ssing
Technical Analyst
Federated Insurance Companies of Canada
http://www.federated.ca maintenant disponible en Fran=E7ais=20

veritas-bu-admin AT mailman.eng.auburn DOT edu wrote on 08/19/2003 01:03:54 PM:

>  =20
> L700 StoredgeTek Tape Library=20
> NBU 4.5 MP3 on Solaris 8=20
>  =20
> Does anybody know if it is okay to open the door of the L700 robot=20
> hosted by the Master Server while Netbackup is still running? I just
> want to inspect why two drives are DOWN. I plan on only having the=20
> door open long enough to inspect the drives and clear any problems.=20
> I can't wait to shutdown Netbackup because there are too many jobs=20
> running and queued all of the time and I have been waiting for three
> days to look at these two DOWN drives.=20
>  =20
> Paul Griese=20
> System Administrator=20
> Telecheck Services=20
> Houston, Texas=20
> _________________________________________________________________________=
____=20
>=20
> (c) 2003 TeleCheck International, Inc. THIS DOCUMENT, AND ANY=20
> ATTACHED INFORMATION: 1) IS PROPRIETARY, PRIVILEGED AND CONFIDENTIAL
> PROPERTY OF TELECHECK UNDER APPLICABLE LAW, AND 2) IS INTENDED=20
> EXCLUSIVELY FOR INTERNAL USE BY TELECHECK EMPLOYEES AND INTENDED=20
> RECIPIENTS WITH A LEGITIMATE TELECHECK BUSINESS NEED THEREFORE. ITS=20
> REPRODUCTION, DISSEMINATION, DISTRIBUTION AND/OR DISCLOSURE, EXCEPT=20
> TO SUCH TELECHECK EMPLOYEES AND INTENDED RECIPIENTS, IS STRICTLY=20
> PROHIBITED . IF YOU ARE NOT SUCH A TELECHECK EMPLOYEE OR INTENDED=20
> RECIPIENT, OR THE EMPLOYEE OR AGENT RESPONSIBLE FOR DELIVERING THIS=20
> MESSAGE TO THE INTENDED RECIPIENT, YOU ARE HEREBY NOTIFIED THAT ANY=20
> REPRODUCTION, DISSEMINATION, DISTRIBUTION AND/OR DISCLOSURE OF THIS=20
> DOCUMENT, OR ANY ATTACHMENTS, IS STRICTLY PROHIBITED.=20
>=20
>=20

----=_NextPart_ST_14_53_18_Tuesday_August_19_2003_11399
Content-Type: text/html; charset=ISO-8859-1
Content-Transfer-Encoding: quoted-printable
Content-Description: HTML

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<HTML><HEAD>
<META http-equiv=3DContent-Type content=3D"text/html; charset=3Diso-8859-1"=
>
<META content=3D"MSHTML 6.00.2800.1170" name=3DGENERATOR></HEAD>
<BODY style=3D"MARGIN-TOP: 2px; FONT: 10pt Tahoma; MARGIN-LEFT: 2px">
<DIV>We have opened the doors on our L700 libraries while jobs were running=
 with=20
no ill-effects. Granted we're not that busy all the time. Basically the onl=
y=20
thing you might lose is a couple of robotic mounts which NBU may make you m=
ount=20
manually because the robot was unavailable while the door was open. I can't=
 say=20
this for sure because it's never happened to us ... but it was something we=
=20
thought about when we opened the door the 1st time. Good luck.</DIV>
<DIV>&nbsp;</DIV>
<DIV>Dennis</DIV>
<DIV>&nbsp;</DIV>
<DIV>Dennis F. Dwyer<BR>Manager, Systems Software<BR>Tampa Electric=20
Company</DIV>
<DIV>&nbsp;</DIV>
<DIV>(813) 225-5181&nbsp; - Voice<BR>(813) 275-3599&nbsp; - FAX</DIV>
<DIV>&nbsp;</DIV>
<DIV>Visit our corporate website at <A=20
href=3D"http://www.tecoenergy.com";>www.tecoenergy.com</A></DIV>
<DIV>&nbsp;</DIV>
<DIV>The Master Chief Says: "Time is not a test of the truth"<BR>Translatio=
n:=20
Just because you've always done it that way, doesn't make it=20
right<BR><BR>&gt;&gt;&gt; &lt;Karl.Rossing AT Federated DOT CA&gt; 08/19/2003 
2:22=
:52=20
PM &gt;&gt;&gt;<BR><BR><FONT face=3Dsans-serif size=3D2>I have opened the d=
oor on my=20
SUN L400(Exabyte 220 library) with 2 drives and 4 trays while netbackup was=
=20
running to inject new media.</FONT> <BR><BR><FONT face=3Dsans-serif size=3D=
2>I=20
didn't run into problems. I just made sure that the arm wasn't picking=20
tapes.</FONT> <BR><BR><FONT face=3Dsans-serif size=3D2>For the L700 it migh=
t be=20
different.<BR></DIV></FONT>
<DIV>
<HR>
</DIV>
<DIV><FONT size=3D3>Karl-Fr=E9d=E9ric R=F6ssing<BR>Technical Analyst<BR>Fed=
erated=20
Insurance Companies of Canada<BR>http://www.federated.ca maintenant disponi=
ble=20
en Fran=E7ais</FONT> <BR><BR><FONT=20
size=3D2><TT>veritas-bu-admin AT mailman.eng.auburn DOT edu wrote on 08/19/2003 
01=
:03:54=20
PM:<BR><BR>&gt; &nbsp;</TT></FONT> <BR><FONT size=3D2><TT>&gt; L700 Storedg=
eTek=20
Tape Library</TT></FONT> <BR><FONT size=3D2><TT>&gt; NBU 4.5 MP3 on Solaris=
=20
8</TT></FONT> <BR><FONT size=3D2><TT>&gt; &nbsp;</TT></FONT> <BR><FONT=20
size=3D2><TT>&gt; Does anybody know if it is okay to open the door of the L=
700=20
robot <BR>&gt; hosted by the Master Server while Netbackup is still running=
? I=20
just<BR>&gt; want to inspect why two drives are DOWN. I plan on only having=
 the=20
<BR>&gt; door open long enough to inspect the drives and clear any problems=
=2E=20
<BR>&gt; I can't wait to shutdown Netbackup because there are too many jobs=
=20
<BR>&gt; running and queued all of the time and I have been waiting for=20
three<BR>&gt; days to look at these two DOWN drives.</TT></FONT> <BR><FONT 
size=3D2><TT>&gt; &nbsp;</TT></FONT> <BR><FONT size=3D2><TT>&gt; Paul=20
Griese</TT></FONT> <BR><FONT size=3D2><TT>&gt; System Administrator</TT></F=
ONT>=20
<BR><FONT size=3D2><TT>&gt; Telecheck Services</TT></FONT> <BR><FONT=20
size=3D2><TT>&gt; Houston, Texas</TT></FONT> <BR><FONT size=3D2><TT>&gt; 
___________________________________________________________________________=
__</TT></FONT>=20
<BR><FONT size=3D2><TT>&gt; <BR>&gt; (c) 2003 TeleCheck International, Inc.=
 THIS=20
DOCUMENT, AND ANY <BR>&gt; ATTACHED INFORMATION: 1) IS PROPRIETARY, PRIVILE=
GED=20
AND CONFIDENTIAL<BR>&gt; PROPERTY OF TELECHECK UNDER APPLICABLE LAW, AND 2)=
 IS=20
INTENDED <BR>&gt; EXCLUSIVELY FOR INTERNAL USE BY TELECHECK EMPLOYEES AND 
INTENDED <BR>&gt; RECIPIENTS WITH A LEGITIMATE TELECHECK BUSINESS NEED=20
THEREFORE. ITS <BR>&gt; REPRODUCTION, DISSEMINATION, DISTRIBUTION AND/OR 
DISCLOSURE, EXCEPT <BR>&gt; TO SUCH TELECHECK EMPLOYEES AND INTENDED RECIPI=
ENTS,=20
IS STRICTLY <BR>&gt; PROHIBITED . IF YOU ARE NOT SUCH A TELECHECK EMPLOYEE =
OR=20
INTENDED <BR>&gt; RECIPIENT, OR THE EMPLOYEE OR AGENT RESPONSIBLE FOR DELIV=
ERING=20
THIS <BR>&gt; MESSAGE TO THE INTENDED RECIPIENT, YOU ARE HEREBY NOTIFIED TH=
AT=20
ANY <BR>&gt; REPRODUCTION, DISSEMINATION, DISTRIBUTION AND/OR DISCLOSURE OF=
 THIS=20
<BR>&gt; DOCUMENT, OR ANY ATTACHMENTS, IS STRICTLY PROHIBITED.</TT></FONT> 
<BR><FONT size=3D2><TT>&gt; <BR>&gt; <BR></DIV></TT></FONT></BODY></HTML>

----=_NextPart_ST_14_53_18_Tuesday_August_19_2003_11399--


<Prev in Thread] Current Thread [Next in Thread>