Veritas-bu

[Veritas-bu] Summary - tldd failing

2003-01-21 11:44:13
Subject: [Veritas-bu] Summary - tldd failing
From: rene_casalme AT baxter DOT com (rene_casalme AT baxter DOT com)
Date: Tue, 21 Jan 2003 08:44:13 -0800
Thanks to all who responded.

As suggested by a number of people, I used the
/usr/openv/volmgr/bin/tpconfig command to update my existing robot
changer's device file.  I restarted the netbackup daemons afterwards.


Another Veritas guru provided me with the following instructions using the
admin GUI.
>From the GUI, select the robot and right click it and choose "change".
When
the robot configuration screen comes up verify a few entries:

* Robot type TLD
* Robot is controlled locally by this device host (Local)
* Make the change to the robotic device file by either browsing to select
or
manually type:
o /dev/sg/c1t1l0

Stop the media manager daemons and restart them.


Again, thanks to everyone.  I've included my original post for those who've
missed it.

Rene

Here is my original post.

On 1/20/03 4:56 PM, "rene_casalme AT baxter DOT com" <rene_casalme AT baxter 
DOT com>
wrote:

> -----------I get this from the /var/adm/messages file:
>
> Jan 20 13:48:56 USDCdbsvr1 tldcd[11338]: [ID 321662 daemon.error] TLD(0)
> Mode_sense error, CHECK CON
> DITION
> Jan 20 13:48:56 USDCdbsvr1 tldd[11334]: [ID 320639 daemon.error] TLD(0)
> unavailable: initialization
> failed: Unable to sense robotic device
>
> ------------This is what I get from "sgscan all".
>
> /dev/sg/c0t0l0: Disk (/dev/rdsk/c0t0d0): "FUJITSU MAN3367M SUN36G"
> /dev/sg/c0t3l0: Processor: "SUN     D240"
> /dev/sg/c0t6l0: Tape (/dev/rmt/0): "HP      C5683A"
> /dev/sg/c1t0l0: Disk (/dev/rdsk/c1t0d0): "FUJITSU MAN3367M SUN36G"
> /dev/sg/c1t1l0: Changer: "HP      C7200-8000"
> /dev/sg/c1t1l1: Tape (/dev/rmt/1): "QUANTUM DLT8000"
> /dev/sg/c1t1l2: Tape (/dev/rmt/2): "QUANTUM DLT8000"
> /dev/sg/c1t2l0: Processor: "SUN     D240"
> /dev/sg/c1t3l0: Disk (/dev/rdsk/c1t3d0): "SEAGATE ST336605LSUN36G"
> /dev/sg/c1t4l0: Disk (/dev/rdsk/c1t4d0): "SEAGATE ST336605LSUN36G"
> /dev/sg/c1t6l0: Cdrom: "TOSHIBA DVD-ROM SD-M1401"
>
>
> ------------When I do a robtest, it points to the wrong devices:
>
> [root@USDCdbsvr1 goodies]# robtest
> Configured robots with local control supporting test utilities:
> TLD(0)     robotic path = /dev/sg/c1t0l0
>
> Robot Selection
> ---------------
> 1)  TLD 0
> 2)  none/quit
> Enter choice: 1
>
> Robot selected: TLD(0)   robotic path = /dev/sg/c1t0l0
>
> Invoking robotic test utility:
> /usr/openv/volmgr/bin/tldtest -r /dev/sg/c1t0l0 -d1 /dev/rmt/1cbn -d2
> /dev/rmt/2cbn
>
> Opening /dev/sg/c1t0l0
> mode_sense failed, CHECK CONDITION
> sense key = 0x5, asc = 0x24, ascq = 0x0, INVALID FIELD IN CDB
> Enter tld commands (? returns help information)
>
> ------------ How do I tell it to look in to the /dev/sg/c1t1l0 as the
> changer?
>
> ------------ Or am I wrong?  And the problem lies elsewhere?
>
> Rene Casalme
>



<Prev in Thread] Current Thread [Next in Thread>
  • [Veritas-bu] Summary - tldd failing, rene_casalme AT baxter DOT com <=