Are all of the slots in your VLS filled with tapes?

I know with one of the old ATL libraries, if you manually removed a tape and
didn't "press" it in first to have it spring eject, it thought  a tape still
lived in the slot and subsequently failed with a similar error.

David

<><><><><><><><><><><><><><><><><><><><>
David A. Chapa
Backup Storage Consultant
DataStaff, Inc.
http://www.datastaff.com
312 683 1144
---------------------------------------

-----Original Message-----
From: veritas-bu-admin AT mailman.eng.auburn DOT edu
[mailto:veritas-bu-admin AT mailman.eng.auburn DOT edu]On Behalf Of DP
Sent: Thursday, August 22, 2002 5:01 AM
To: veritas-bu AT mailman.eng.auburn DOT edu
Subject: [Veritas-bu] initialize_element_status failed (202 error?)


Hello all:

I have NetBackup 3.4.1GA installed on a Sun Ultra 2 running Solaris 8. This
system has worked for some time with an ATL L200 DLT4000 library attached.

Running low on capacity, I recently connected an ADIC VLS DLT2000 library.
The library is properly connected and addressed by the system as far as I
can see (probe-scsi shows it where it's supposed to be, not conflicting,
etc). The library will set up in NetBackup just fine, but if I try to
inventory it we get the following:

robot inventory failed: Unable to sense robotic device (202)

Furthermore, on boot, when the Media Manager daemons start, I get:

TLD(1) key = 0x5, asc = 0x24, ascq = 0x0, INVALID FIELD IN CDB
TLD(1) transport read_element_status error, CHECK CONDITION
TLD(1) unavailable: initialization failed: Unable to sense robotic device

In an attempt to troubleshoot this I played around with robtest...
Everything in robtest works (rezero, move media around, etc), except "init"
-- if I use the "init" command, I get:

Initiating INITIALIZE_ELEMENT_STATUS
Initialize_element_status failed, CHECK CONDITION
Sense key = 0x5, asc = 0x24, ascq = 0x0, INVALID FIELD IN CDB

(noticing a pattern here, are we? :-) )

I've looked at this to the extent of my ability, and wondering if anyone
else has a suggestion that might get this library up and going.