[Veritas-bu] Buying a new Robot
2001-09-14 09:49:19
Subject: |
[Veritas-bu] Buying a new Robot |
From: |
fx AT veritas DOT com (fx [François-Xavier Peretmere]) |
Date: |
Fri, 14 Sep 2001 15:49:19 +0200 |
> From: W. Curtis Preston [mailto:curtis AT backupcentral DOT com]
> Sent: Wednesday 05 September, 2001 18:17
> I also really like the Scalar, but this is not the first time
> I've heard about this problem between NetBackup and the Scalar 1000.
> I wonder if this is a problem with NetBackup, or with goofiness associated
> with the Scalar? I wonder if the 10,000 also has this problem.
>
> I wonder if this problem will exist forever, or if someone at
> Veritas is working with anyone at ADIC to make this problem go away.
i recently worked with a customer who bought a Scalar 100 / LTO.
you need the latest Scalar firmware version to enable the mailslot
auto inventory by the robot, with the vm.conf AUTO_UPDATE_ROBOT.
hth,
fx
#include <VRTS/std_disclaimer.h>
--
fx AT veritas DOT com | Having been erased,
François-Xavier Peretmere | The document you're seeking
http://www.veritas.com/ | Must now be retyped.
|
|
|