Date: Wed, 5 Sep 2001 09:41:44 -0500
On Wed, Sep 05, 2001 at 08:36:07AM -0500, dayal singh wrote:

Dayal,

1) I would check on how scsi<->fc bridges logging to fabric/AL 
it could be wrong topology
2) If you are using brocade switches, it could be wrong OS setting. 
For HP and AL we had to setup NT. 
3) I would check on HBA driver. If there is newer version is available
4) Firmware on the bridges could be old.     

It looks like you got all hardware from HP, so you should be able to get 
answer what exactly was tested and recommended by HP, drivers, patches. 


Thanks,
Andrew



 

> NBU GURUs,
>                           We are continuously experiencing SCSI reset erros 
> and the drives are being downed on some of the drives.  Most of the time it 
> happens on the specific drives, sometimes it affects other drives also. I am 
> running NBU DataCenter 3.4 on HP-UX 11.0, N-class machine and I have twenty  
> Quantum DLT8000 drives, connected through fiber to a SureStore L700 tape 
> library over HP fiber-scsi bridges. The bridges have a firmware of 4040.
> 
> Anyone has seen these errors, any fixes i.e patches etc  ?
> 
> Y'r resonse is greatly appreciated.
> 
> TIA
> 
> Dayal
> 
> 
> Get 250 color business cards for FREE!
> http://businesscards.lycos.com/vp/fastpath/
> _______________________________________________
> Veritas-bu maillist  -  Veritas-bu AT mailman.eng.auburn DOT edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

-- 
----
Andrew Shinkarev
Network Systems Specialist
Abbott Laboratories
(847) 9387559
shinkara AT pprd.abbott DOT com