Shouldn't be a problem.  I can't think of any show 
stoppers.  

You'll just want to make sure that you have your robot 
configured properly at the hot site (robnum, devfile, 
etc.)

Perhaps one of the things that I would do after you 
recover the databases at your hot site would be to move 
all of the tapes to NON-ROBOTIC or STANDALONE then Auto-
Inventory the library.

other than that I think you should be okay.

David

Quoting Daniel Monjar <dam AT orgtek DOT com>:

> what would be involved with changing tape libraries 
at a disaster
> recovery test?  Say I'm using a Quantum/ATL robot 
here and have to use
> a Storage-Tek robot there.  Is this a large problem?
>
> --
> Daniel Monjar (mailto:dmonjar AT orgtek DOT com)
> "Never underestimate the power of stupid people in 
large groups."
>