Veritas-bu

[Veritas-bu] Device Daemon

2000-11-06 11:40:24
Subject: [Veritas-bu] Device Daemon
From: David A. Chapa david AT datastaff DOT com
Date: Mon, 6 Nov 2000 10:40:24 -0600 (CST)
I've never had that problem with 3.2 and later, but did 
see this type of behaviour in previous versions.

when this happens, try executing this command

$NBUHOME/bin/admincmd/bpschedreq -read_stunits

Like I said this shouldn't hanging and if it persists 
you should open a call with Veritas, as it may be a 
symptom of something bigger.

Incidentally, are you using AIT by chance.

David

Quoting "Buffington, Devon" 
<Devon_Buffington AT AIMFUNDS DOT COM>:

> Has anyone had problems with their device daemon 
hanging up? Or daemon
> either "hangs", where there are jobs waiting in the 
queue, but the drives
> are empty, so they aren't waiting for anything except 
the robot to get the
> tapes, basically. Then the daemon seems to just die 
at other times, with no
> directly attributable cause.
> We seem to have started having this happen fairly 
regularly sometime after
> we added the 443 patch. I do not know if the patch 
has anything to do with
> it or not.
> Any help would be greatly appreciated.
>
> Devon Buffington
>
> 



~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
David A. Chapa                847 413 1144 p
DataStaff, Inc.               847 413 1168 f



<Prev in Thread] Current Thread [Next in Thread>