Re: [Networker] SELinux and networker
2009-06-25 19:20:14
Hi Rick,
On 26/06/2009, at 01:13 , Rich Graves wrote:
This has worked for me for about a year, on both client and server.
The textrel_shlib change is fairly common for proprietary binaries.
semanage fcontext -a -t textrel_shlib_t "/usr/lib/nsr(/.*)?"
semanage fcontext -a -t var_log_t "/nsr/logs(/.*)?"
restorecon -R /usr/lib/nsr
restorecon -R /nsr/logs
Another approach for the logs is to edit syslog.conf and drop them
in /var/log instead of /nsr/logs.
Thanks for posting the tip. I just tried it out on a CentOS 5.3 (aka
RHEL 5) system in my lab that had previously failed to work with 7.5
with SELinux ... worked a treat.
Maybe the next step would be to get these details officially added to
EMC's installation guide... :-)
Cheers,
Preston.
--
Preston de Guise
"Enterprise Systems Backup and Recovery: A Corporate Insurance Policy":
http://www.amazon.com/Enterprise-Systems-Backup-Recovery-Corporate/dp/1420076396
http://www.enterprisesystemsbackup.com
NetWorker blog: http://nsrd.wordpress.com
To sign off this list, send email to listserv AT listserv.temple DOT edu and type
"signoff networker" in the body of the email. Please write to networker-request
AT listserv.temple DOT edu if you have any problems with this list. You can access the
archives at http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
|
|
|