Re: [Networker] Volume name/barcode mismatch
2007-06-14 12:32:55
On Jun 14, 2007, at 11:45 AM, Lauradel Collins wrote:
Hm. Well, I did use "deposit" in my jukebox and it worked.
Since this jb has only one cartridge slot for loading cartridges,
this unloading/loading one at a time via gui/command line is more
interactive than just using the jb to unload the tapes, reload new
tapes, and using nsrjb -IE to reset the jb.
Though next time I need to move a lot of tapes, I'll try this -d/-w
routine and see if it really is more annoying.
When you just take cartridge out or put new ones in without using
nsrjb -d/w, you are changing the state of the tape library away from
what NetWorker's media database expects it to be. This is why you end
up having to reset it via nsrjb -IE. If you follow best practices
with loading and unloading cartridges, then you shouldn't need to use
nsrjb -IE.
To sign off this list, send email to listserv AT listserv.temple DOT edu and type
"signoff networker" in the body of the email. Please write to networker-request
AT listserv.temple DOT edu if you have any problems with this list. You can access the
archives at http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
|
|
|