Hi,
I am currently getting a problem backing up our Netware 6.5 SP5 server
running the Networker client 7.2 Combi1 patch.
The backup of the volumes SYS, MAIL, ARCHIVE get backed up more that once.
When the backup of the volume completes its starts all over again and and
this can happen from 2 times to 4 times. On the odd occasion it only
happens once and finishs properly. The repeats fill up our 2 (~40GB) DLT
tapes. {Incrementals are OK}
Server side is Networker 7.2.1 Build 311 running on W2k SP4
In the daemon.log I get the error
05/18/06 09:08:35 nsrd: savegroup info: starting Rerun (with 1 client(s))
05/18/06 09:10:04 nsrd: ikwnb:ARCHIVE: saving to pool 'ITSS' (ITSS_28)
05/18/06 09:12:20 nsrindexd: pid 2324 frag size 774910001, invalidating
connection
05/18/06 09:19:12 nsrd: ikwnb:ARCHIVE: done saving to pool 'ITSS' (ITSS_28)
1467 MB
05/18/06 09:19:17 savegrp: ikwnb:ARCHIVE: will retry 2 more time(s)
05/18/06 09:19:19 nsrd: ikwnb:ARCHIVE: saving to pool 'ITSS' (ITSS_28)
05/18/06 09:27:45 nsrindexd: pid 3088 frag size 842608176, invalidating
connection
05/18/06 09:28:43 nsrd: ikwnb:ARCHIVE: done saving to pool 'ITSS' (ITSS_28)
1467 MB
05/18/06 09:28:48 savegrp: ikwnb:ARCHIVE: will retry 1 more time(s)
05/18/06 09:28:50 nsrd: ikwnb:ARCHIVE: saving to pool 'ITSS' (ITSS_28)
05/18/06 09:38:11 nsrd: ikwnb:ARCHIVE: done saving to pool 'ITSS' (ITSS_28)
1467 MB
05/18/06 09:38:19 nsrd: ikwmb.ad.itss.nerc.ac.uk:index:ikwnb saving to pool
'ITSS' (ITSS_28)
05/18/06 09:39:02 nsrd: ikwmb.ad.itss.nerc.ac.uk:index:ikwnb done saving to
pool 'ITSS' (ITSS_28) 230 MB
05/18/06 09:39:08 nsrd: savegroup notice: Rerun completed, total 1
client(s), 0 Hostname(s) Unresolved, 0 Failed, 1 Succeeded.
* ikwnb:ARCHIVE: SAVE.NLM: RPC error: RPC send operation failed. A network
connection could not be established with the host.
* ikwnb:ARCHIVE: SAVE.NLM: RPC error: RPC send operation failed. A network
connection could not be established with the host.
* ikwnb:ARCHIVE: SAVE.NLM: shutdown failed
* ikwnb:ARCHIVE: 1 retry attempted
* ikwnb:ARCHIVE: SAVE.NLM: RPC error: RPC send operation failed. A network
connection could not be established with the host.
* ikwnb:ARCHIVE: SAVE.NLM: RPC error: RPC send operation failed. A network
connection could not be established with the host.
* ikwnb:ARCHIVE: SAVE.NLM: shutdown failed
05/18/06 09:39:53 nsrd: write completion notice: Writing to volume ITSS_28
complete
Would the nwlib6g.exe (Novell patch) fix this RPC error perhaps? It is Beta
at the moment so I am a bit reluctant to put it on.
Many thanks for any help
Regards
Surinder.
To sign off this list, send email to listserv AT listserv.temple DOT edu and
type "signoff networker" in the
body of the email. Please write to networker-request AT listserv.temple DOT edu
if you have any problems
wit this list. You can access the archives at
http://listserv.temple.edu/archives/networker.html or
via RSS at http://listserv.temple.edu/cgi-bin/wa?RSS&L=NETWORKER
|