Antonio,

Nope sorry, you can't.

Greg

|
| I have checked and the cleaning tape i have are SEAGATE LTO CLEAN TAPE.
| So I can't use with the IBM driver?
|
|       -----Messaggio originale-----
|       Da: Gregory Demilde - System Support Engineer
[mailto:Gregory.Demilde AT Sun DOT COM]
|       Inviato: ven 16/05/2003 14.29
|       A: NETWORKER AT LISTMAIL.TEMPLE DOT EDU; Antonio Ettorre
|       Cc:
|       Oggetto: Re: [Networker] Cleaning Tape on L700
|
|
|
|
|       Or the wrong set of of labels
|       Antonio,
|
|       You might have the wrong tapes or the wrong barcode.
|
|       The barcode is standardize this way for the cleaning tapes
|
|       CLN     = Cleaning tape
|       S       = Vendor is Seagate (I=IBM, H=HP and U=Universal)
|       XX      = number
|
|       The L700 is smart enough to detect, from the barcode, for which tape
vendor is
|       the cleaning tape made for. If you can go for "U", those are universal
and do
|       work for all vendors
|
|       If you look at the tape itself, you will also see the letter of the tape
vendor
|       type : H, S, I or U. Of course, the type on the tape media has to match
the type
|       on the barcode.
|
|       Hope this helps
|       Greg
|
|
|       | Date: Fri, 16 May 2003 08:12:33 -0400
|       | From: Antonio Ettorre <antonio.ettorre AT ERPTECH DOT IT>
|       | Subject: Re: [Networker] Cleaning Tape on L700
|       | To: NETWORKER AT LISTMAIL.TEMPLE DOT EDU
|       |
|       | My drives si an IBM and not Seagate as you can see from an inquire:
|       |
|       | [email protected]:STK     L700            0304|Autochanger (Jukebox)
|       | [email protected]:IBM     ULTRIUM-TD1     27Q1|Tape, /dev/rmt/1cbn
|       | [email protected]:IBM     ULTRIUM-TD1     27Q1|Tape, /dev/rmt/2cbn
|       | [email protected]:IBM     ULTRIUM-TD1     27Q1|Tape, /dev/rmt/3cbn
|       | [email protected]:IBM     ULTRIUM-TD1     27Q1|Tape, /dev/rmt/4cbn
|       |
|       | So do you think I have one wrong set of cleaning tape?
|       |
|       |
|       | On Fri, 16 May 2003 06:57:33 -0400, Davina Treiber
<treiber AT HOTPOP DOT COM>
|       | wrote:
|       |
|       | >On Fri, 16 May 2003 06:35:03 -0400, Antonio Ettorre
|       | ><antonio.ettorre AT ERPTECH DOT IT> wrote:
|       | >
|       | >>    I have still another problem with one L700 that i use. The
backup
|       | >>server in a SF3800 with Solaris 8 and Networker 6.1.3.Build.428
|       | >>When i try to mount a cleaning tape or Networker try to do an
automatic
|       | >>cleaning i have this error:
|       | >>nsrd: Jukebox 'STK_L700' failed: Illegal Request, Incompatible
Medium
|       | >>Installed
|       | >>
|       | >>But I can see correctly the cleaning tape in the slot as follow:
|       | >>#nsrjb -C -j STK_L700
|       | >>
|       | >>381: Cleaning Tape (5 uses left)
|       | CLNS00                                   -
|       | >>382: Cleaning Tape (5 uses left)
|       | CLNS01                                   -
|       | >>383: Cleaning Tape (5 uses left)
|       | CLNS02                                   -
|       | >>384: Cleaning Tape (5 uses left)
|       | CLNS03                                   -
|       | >>
|       | >>I also try to do this:
|       | >># nsrjb -j STK_L700 -l -T CLNS00
|       | >>nsrjb: Jukebox error:  Fri 12:31:53 barcode CLNS00 not found
|       | >
|       | >Is this the right type of cleaning tape with the right label? CLNS
means it
|       | >is a Seagate cleaning tape for a Seagate LTO drive. Nothing else is
|       | >compatible.
|       | >
|       | >--
|       | >Note: To sign off this list, send a "signoff networker" command via
email
|       | >to listserv AT listmail.temple DOT edu or visit the list's Web site 
at
|       | >http://listmail.temple.edu/archives/networker.html where you can
|       | >also view and post messages to the list.
|       | >=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=
|       |
|       | --
|       | Note: To sign off this list, send a "signoff networker" command via
email
|       | to listserv AT listmail.temple DOT edu or visit the list's Web site at
|       | http://listmail.temple.edu/archives/networker.html where you can
|       | also view and post messages to the list.
|       | =*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=
|
|       ____________________________________________________________________
|       Gregory Demilde - Product Support Group - Sun Services Belgium
|       Phone : +32 2 704 8891, Fax : +32 2 704 80 80
|       Mobile : +32 475 720340, Email : Gregory.Demilde AT sun DOT com
|
|
|
|

____________________________________________________________________
Gregory Demilde - Product Support Group - Sun Services Belgium
Phone : +32 2 704 8891, Fax : +32 2 704 80 80
Mobile : +32 475 720340, Email : Gregory.Demilde AT sun DOT com

--
Note: To sign off this list, send a "signoff networker" command via email
to listserv AT listmail.temple DOT edu or visit the list's Web site at
http://listmail.temple.edu/archives/networker.html where you can
also view and post messages to the list.
=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=

<Prev in Thread] Current Thread [Next in Thread>