Re: [Bacula-users] Issues with IBM Labels
2017-05-05 05:00:15
I already wrote this previously: the error message produced by Bacula
indicates that the user has enabled ANSI volume labels. This is unusual
and generally not needed unless you have multiple different backup/other
programs using the tapes. In any case, if you explicitly enable this
ANSI tape label option in Bacula (turned off by default), you are
limited to 6 characters in the tape name. Without the ANSI tape label
option in the bacula-sd.conf file, your tape labels may be up to 127
characters in length.
As I previously wrote, I think that the user is confusing barcodes and
reading barcodes with the ANSI tape labels feature in Bacula.
Best regards,
Kern
On 05/05/2017 10:46 AM, Ralf Brinkmann wrote:
> Am 18.04.2017 um 04:00 schrieb Jim Richardson:
>> I must be missing something stupid. I am using IBM barcode labels on
>> LTO7 tapes. Bacula labeled my media, but I am unable to start backup
>> job due to error Fatal error: ansi_label.c:296 ANSI Volume label name
>> "000009L7" longer than 6 chars.
> Just looked into our old DELL PowerVault web interface. Years ago for
> the same lable length I configured:
>
>> Configure Library
>> General
>> Barcode Label Length Reported To Host = 8
> I included the two trailing digits for the tape type into the label length.
>
------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most