Re: [Bacula-users] [Bacula-devel] Load slots timeout
2014-11-10 07:13:45
Hi.
It's in devel because the question about editing sources, but not
about configuration.
And I think solve the question could only developer.
The conclusion to change the code is premature.
Hi guys.
I use bacula 5.2.13 with IBM TS3200 library.
Periodically I face problem with load slot time out. In
logs it looks lilke:
22-Sep 00:35 baculasrv-dir JobId 10471:
Recycled volume "220AAAL6"
22-Sep 00:35 baculasrv-sd JobId 10471:
3304 Issuing autochanger "load slot 1, drive 1"
command.
22-Sep 00:40 baculasrv-sd JobId 10471:
Fatal error: 3992 Bad autochanger "load slot 1, drive
1": ERR=Child died from signal 15: Termination.
Results=Program killed by Bacula
(timeout)
22-Sep 00:32 sqcompose-fd JobId 10471:
Fatal error: backup.c:1019 Network send error to SD.
As I understood, bacula tries to load slot for 5 minutes
and if it's not successful stops job.
I started investigation why bacula sometimes doesn't
manage to load slot in 5 minutes and find out library
stops responding to commands and starts cleaning drive
procedure which takes more than 5 minutes(Library was
configured to clean drive automatically)
So how can I solve the problem?
I've found place in mtx-changer script where declared
300 seconds to wait. I've increased it value to 1800
seconds. Is it only place or I have to change somthing
else in sources?
Hi everybody.
Increasing timeout in mtx-changer script hasn't helped, I
have the same issue. Where in sources I can increase timeout
to 30 minutes?
I don’t see why this is on devel It should be on users, which is
cc’d here.
|
------------------------------------------------------------------------------
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net