On 09/04/2014 02:23 PM, Josh Fisher wrote:
...
> One possibility is that you need to do a 'update slots' command to bring
> Bacula
> into sync. If anything has changed with regard to which volumes are currently
> online, then the update slots command is necessary to bring Bacula back into
> sync.
Hmm. So after you delete a volume, you need to run 'update slots'?
Because I have deleted some volumes and now I got 'Volume
"vchanger_0011_0021" not found in catalog. Slot=256 InChanger set to zero.'
> Is vchanger_0008_0011 currently available in a slot? Running 'vchanger
> /path/to/vchanger.conf list' will list vchanger's idea of which volumes are
> in
> which slots. The question is why didn't Bacula load vchanger_0008_0011 and
> use
> it? Is Bacula attempting to load it and failing, or does it not even attempt
> to
> load it?
Please keep in mind that this is wrong: after vchanger_0007_0011 fills
up I want vchanger_0007_0012, *not* vchanger_0008_0011. That said:
293:vchanger_0007_0011
294:vchanger_0007_0012
...
340:vchanger_0008_0011
Currently changer's log file is empty, bacula's log is
> Current Volume "vchanger_0007_0011" not acceptable because:
> 1998 Volume "vchanger_0007_0011" status is Full, volume has recycling
> disabled.
> 04-Sep 13:26 holstein-sd JobId 5431: 3307 Issuing autochanger "unload slot
> 293, drive 0" command.
> 04-Sep 13:26 holstein-sd JobId 5431: 3301 Issuing autochanger "loaded? drive
> 0" command.
> 04-Sep 13:26 holstein-sd JobId 5431: 3302 Autochanger "loaded? drive 0",
> result: nothing loaded.
> 04-Sep 13:26 holstein-sd JobId 5431: 3304 Issuing autochanger "load slot 293,
> drive 0" command.
> 04-Sep 13:26 holstein-sd JobId 5431: 3305 Autochanger "load slot 293, drive
> 0", status is OK.
> 04-Sep 13:26 holstein-sd JobId 5431: Warning: Director wanted Volume
> "vchanger_0008_0011".
So it keeps asking for the slot it's just unloaded (because it filled up
& the file size confirms that). I can bump vchanger's log_level up from
LOG_ERR, but this doesn't look like vchanger's problem in the first place.
We'll see if "update slots" fixed anything, but I really don't see why
as the slots in question: 293, 294, and 340 never changed.
--
Dimitri Maziuk
Programmer/sysadmin
BioMagResBank, UW-Madison -- http://www.bmrb.wisc.edu