[Bacula-users] Labeling tapes
2014-09-03 13:03:45
Hello Bacula Users!
I am trying to get Bacula running. I have it working using disk. I just need
it to use my tape drive. I am using Linux CentOS 7 (on Dell 720) and a Dell
DL4000 tape library.
P.S. Note the "Alert Command" setting (as I always get those 50/50 chances
wrong).
ERROR:
03-Sep 11:21 bacula-sd JobId 13: Job DL4000.2014-09-03_11.21.39_05 is waiting.
Cannot find any appendable volumes.
Please use the "label" command to create a new Volume for:
Storage: "Drive1" (/dev/nst0)
Pool: Default
Media type: LTO-6-Drive
CONFIG:
[bacula-dir.conf]
# Definition of DDS tape storage device
Storage {
Name = DL4000
# Do not use "localhost" here
Address = [my FQDN here - RAT] # N.B. Use a fully qualified name here
SDPort = 9103
Password = "[it's a secret]" # password for Storage daemon
Device = Drive1 # must be same as Device in Storage
daemon
Device = Drive2 # must be same as Device in Storage
daemon
Device = Drive3 # must be same as Device in Storage
daemon
Device = Drive4 # must be same as Device in Storage
daemon
Media Type = LTO-6-Drive # must be same MediaType in Storage
daemon
Autochanger = yes # enable for autochanger device
}
[bacula-sd.conf]
# My Attempt to add the Dell DL4000
#
Autochanger {
Name = DL4000
Device = Drive1
Device = Drive2
Device = Drive3
Device = Drive4
Changer Command = "/usr/libexec/bacula/mtx-changer %c %o %S %a %d"
Changer Device = /dev/sg5
}
Device {
Name = Drive1 #
Drive Index = 0
Media Type = LTO-6-Drive
Archive Device = /dev/nst0
AutomaticMount = yes; # when device opened, read it
AlwaysOpen = yes;
RemovableMedia = yes;
RandomAccess = no;
AutoChanger = yes
# #
# # Enable the Alert command only if you have the mtx package loaded
# # Note, apparently on some systems, tapeinfo resets the SCSI controller
# # thus if you turn this on, make sure it does not reset your SCSI
# # controller. I have never had any problems, and smartctl does
# # not seem to cause such problems.
# #
# Alert Command = "sh -c 'tapeinfo -f %c |grep TapeAlert|cat'"
# If you have smartctl, enable this, it has more info than tapeinfo
Alert Command = "sh -c 'smartctl -H -l error %c'"
}
(similar X4 for the rest of drives)
Robert Threet
http://yesistilluseperl.blogspot.com/
____________________________________________________________
Apple's new iPhone?
Look closely. Because as you might guess, Apple is hiding something…
http://thirdpartyoffers.netzero.net/TGL3231/54074283939e742822c7est03duc
------------------------------------------------------------------------------
Slashdot TV.
Video for Nerds. Stuff that matters.
http://tv.slashdot.org/
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- [Bacula-users] Labeling tapes,
RAT <=
|
|
|