Bacula-users

Re: [Bacula-users] Bacula volume on new tapelibrary

2012-07-05 07:46:53
Subject: Re: [Bacula-users] Bacula volume on new tapelibrary
From: Uwe Schuerkamp <uwe.schuerkamp AT nionex DOT net>
To: "Holikar, Sachin (ext)" <sachin.holikar.ext AT siemens DOT com>
Date: Thu, 5 Jul 2012 13:44:16 +0200
On Thu, Jun 28, 2012 at 04:12:17PM +0200, Holikar, Sachin (ext) wrote:
> Thanx but the bextract command halts ,
> 
> host:/opt/bacula/etc # bextract -V AAD371L3 /dev/nst0 /tmp/restore_bacula/
> bextract: butil.c:287 Using device: "/dev/nst0" for reading.
> 28-Jun 15:40 bextract JobId 0: No slot defined in catalog (slot=0) for Volume 
> "AAD371L3" on "Drive-1" (/dev/nst0).
> 28-Jun 15:40 bextract JobId 0: Cartridge change or "update slots" may be 
> required.
> 28-Jun 15:40 bextract JobId 0: 3301 Issuing autochanger "loaded? drive 0" 
> command.
> 28-Jun 15:40 bextract JobId 0: 3302 Autochanger "loaded? drive 0", result is 
> Slot 5. 
> 
> Any idea?

If the volume exists in the catalog from previous experiments, you can
manually set the correct slot for it by using the bconsole 

"update volume" 

command. 

HTH Uwe 



------------------------------------------------------------------------------
Live Security Virtual Conference
Exclusive live event will cover all the ways today's security and 
threat landscape has changed and how IT managers can respond. Discussions 
will include endpoint security, mobile security and the latest in malware 
threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users

<Prev in Thread] Current Thread [Next in Thread>
  • Re: [Bacula-users] Bacula volume on new tapelibrary, Uwe Schuerkamp <=