Hello
recently migrated from bacula 5.0.3 (from apt) to 5.2.3 (from sources) on different hosts. Export the database, import and upgrade from script. All goes fine, but when i try to update slots from console, i get this for all the slots:
3305 Auto-cambiador "carga ranura 23, unidad 0", estado es OK. 3001 Volumen=Incremental-03 Ranura=23 Ninguno VolName para Ranura=23 InChanger establecido en cero.
in english :p
No VolName for Slot=23 InChanger set to zero
slot in list volumes are not upgraded. Bacula can read the label from the tape, but the flag "slot" is not updated.
I can read the label from btape:
/etc/bacula# btape -c bacula-sd.conf /dev/nst0 Granularidad del bloque de cinta es 1024 bytes. btape: butil.c:290 Utilizando el dispositivo: «/dev/nst0» para escritura.
27-dic 17:44 btape JobId 0: 3301 Emitiendo comando auto-cambiador "¿cargado? unidad 0". 27-dic 17:44 btape JobId 0: 3302 Auto-cambiador "¿cargado? unidad 0", el resultado es Ranura 1.
btape: btape.c:477 abrir dispositivo "drive" (/dev/nst0): OK *readlabel btape: btape.c:529 Etiqueta de volumen leida correctamente.
Volumen Label: Id : Bacula 1.0 immortal VerNo : 11 VolName : incremental-03 PrevVolName : VolFile : 0 LabelType : VOL_LABEL
LabelSize : 173 PoolName : Incremental MediaType : LTO2 PoolType : Backup HostName : HOSTNAME Fecha de etiqueta escrito: 08-nov-2011 17:23
The label name and pool name are OK.The volume is on the list volumes on bconsole. Any ideas?
Rgds.
o_0'
------------------------------------------------------------------------------
Write once. Port to many.
Get the SDK and tools to simplify cross-platform app development. Create
new or port existing apps to sell to consumers worldwide. Explore the
Intel AppUpSM program developer opportunity. appdeveloper.intel.com/join
http://p.sf.net/sfu/intel-appdev _______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|