> Hi,
>
> I have an IBM TS3310 (rebadged Quantum Scalar i500), however, I don't
> think your problem is specific to the hardware.
>
> First, can you make sure that your drive numbering is correct? Is
> "drive 0" in fact /dev/nst0? On my systems, sometimes they get mapped
> differently on reboot because I'm not using permanent labels.
>
> So perhaps it is simply that mtx loads drive 0, but drive 0 is in
> fact /dev/nst4 or something.
>
> The 'label' command does nothing more than write a little bit of data
> to the tape, so you can execute all of the steps manually and see if
> they work, e.g. pick a slot, pick a drive, load a tape from that slot
> into that drive with mtx, then write a small bit of data using dd or
> tar or whatever, then rewind, eject unload with mt and/or mtx.
>
> Regards,
> Alex
>
> On Mon, 26 Apr 2010 12:27:25 -0400
> ekke85 <bacula-forum < at > backupcentral.com> wrote:
>
> Quote:
>
>
> ekke85 wrote:
> Quote:
> Hi
>
> I hope someone can help me or point me in the right direction. I have a bran
> new Quantum Scalar i500 with 5 drives and 125 slots. When ever I try to do
> "label barcodes" it fails with timeout errors. Bacula is reading the barcodes
> from the tape drive but is not labeling it.
>
> [snip details]
>
> --
> Alex Chekholko chekh < at > genomics.upenn.edu
Hi Alex
Thanks, you were 100% spot on! I have defined udev rules for my drives and now
it works like it should.
Here is the udev rules in case someone else needs it:
rand-rhbackup3 ]# cat /etc/udev/rules.d/local.rules
#Autochanger
BUS=="scsi", KERNEL=="sg3", ENV{ID_SERIAL}="1ADIC
A0C0209217_LLA", NAME="%k", SYMLINK="changer"
#Tape Drive 1
BUS=="scsi", KERNEL=="nst0", ENV{ID_SERIAL}="3500308c09f692094",
NAME="%k", SYMLINK="Drive1"
#Tape Drive 2
BUS=="scsi", KERNEL=="nst1", ENV{ID_SERIAL}="3500308c09f692098",
NAME="%k", SYMLINK="Drive2"
#Tape Drive 3
BUS=="scsi", KERNEL=="nst2", ENV{ID_SERIAL}="3500308c09f692000",
NAME="%k", SYMLINK="Drive3"
#Tape Drive 4
BUS=="scsi", KERNEL=="nst3", ENV{ID_SERIAL}="3500308c09f692090",
NAME="%k", SYMLINK="Drive4"
#Tape Drive 5
BUS=="scsi", KERNEL=="nst4", ENV{ID_SERIAL}="3500308c09f692004",
NAME="%k", SYMLINK="Drive5"
rand-rhbackup3 bacula]#
[/code]
+----------------------------------------------------------------------
|This was sent by ekke85 AT gmail DOT com via Backup Central.
|Forward SPAM to abuse AT backupcentral DOT com.
+----------------------------------------------------------------------
------------------------------------------------------------------------------
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|