Bacula-users

Re: [Bacula-users] A noob and his autochanger

2009-10-08 18:21:12
Subject: Re: [Bacula-users] A noob and his autochanger
From: Kael Fischer <kael.fischer AT gmail DOT com>
To: Alan Brown <ajb2 AT mssl.ucl.ac DOT uk>
Date: Thu, 8 Oct 2009 16:17:09 -0600
I think I found the problem.

As I said I reset the tapes with:
mt rewind; mt weof ; mt rewind

In that case (although 'label barcodes' seemed to work):
3305 Autochanger "load slot 1, drive 0", status is OK.
3905 Device "LTO-4" (/dev/nsa0) open but no Bacula volume is mounted.

Now I reset the tapes in the same way but with 'mt weof 2'.  This gives:
3305 Autochanger "load slot 1, drive 0", status is OK.
Wrote label to prelabeled Volume "AHK836L4" on device "LTO-4" (/dev/nsa0)

Does this seem plausible?

-Kael

------------------------------------------------------------------------------