Re: [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled
2009-04-21 00:11:30
>> When I try to use the "relabel" command Bacula says:
>> Volume "June08-02" has VolStatus Append. It must be Purged or Recycled
>> before relabeling.
>>
>> Which takes us full circle back to my original question, how can recycle
>> this volume?
>
> Try deleting the volume from bacula using the "delete volume" command.
>
On top of that you will have to erase the tape header. Something like:
mt -f /dev/nst0 rewind
mt -f /dev/nst0 weof
for each tape.
John
------------------------------------------------------------------------------
Stay on top of everything new and different, both inside and
around Java (TM) technology - register by April 22, and save
$200 on the JavaOne (SM) conference, June 2-5, 2009, San Francisco.
300 plus technical and hands-on sessions. Register today.
Use priority code J9JMT32. http://p.sf.net/sfu/p
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|
<Prev in Thread] |
Current Thread |
[Next in Thread>
|
- [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled, Erik Lucero
- Re: [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled, Jari Fredriksson
- Re: [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled, Arno Lehmann
- Re: [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled, Erik Lucero
- Re: [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled, John Drescher
- Re: [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled, Timo Neuvonen
- Re: [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled, Erik Lucero
- Re: [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled, Mordechai T. Abzug
- Re: [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled,
John Drescher <=
- Re: [Bacula-users] Tapes not recycling: VolStatus = Error, all job are stalled, Jari Fredriksson
|
|
|