Hi Julien,

this tapes were empty when I added the EOT.
To explain:
I made a full backup to tape mba022, added the EOT and wrote an inc in a 
different pool (for example tape mba056). This was working. The next inc 
to tape mba056 failed.


Julien Cigar schrieb:
> You can switch EOT model only when starting from scratch with empty
> tapes, so that's normal ...
>
>
> On Tue, 2008-12-09 at 08:40 +0100, Stefan Lubitz wrote:
>   
>> Hi all,
>>
>> sine I have added the Paramters:
>>   BSFatEOM = yes;
>>   TWOEOF = yes;
>>   OfflineonUnmount = yes;
>>
>> the system reports the error: The number of files mismatch!
>> It is every time only one file. For Example:
>> Volume=3 Catalog=4 or
>> Volume=350 Catalog=351
>>
>> Have I missed something in the manual? Is there an additional parameter 
>> which needs to be set?
>> I set this Parameters to get rid of some other error messages:
>>
>> BSFatEOM and TWOEOF for:
>> 06-Dec 01:15 backup03-sd JobId 37: Error: block.c:568 Write error at 30:5629 
>> on device "Drive-1" (/dev/nst0). ERR=Input/output error.
>> 06-Dec 01:15 backup03-sd JobId 37: Error: Error writing final EOF to tape. 
>> This Volume may not be readable.
>> dev.c:1681 ioctl MTWEOF error on "Drive-1" (/dev/nst0). ERR=Input/output 
>> error.
>>
>> and:
>> OfflineUnmount for:
>> 06-Dec 01:15 backup03-sd JobId 37: 3301 Issuing autochanger "loaded? 
>> drive 0" command.
>>
>> 06-Dec 01:15 backup03-sd JobId 37: 3302 Autochanger "loaded? drive 0", 
>> result is Slot 22.
>> 06-Dec 01:15 backup03-sd JobId 37: 3307 Issuing autochanger "unload slot 22, 
>> drive 0" command.
>> 06-Dec 01:15 backup03-sd JobId 37: 3995 Bad autochanger "unload slot 22, 
>> drive 0": ERR=Child exited with code 1
>> Results=Unloading Data Transfer Element into Storage Element 22...mtx: 
>> Request Sense: Long Report=yes
>> mtx: Request Sense: Valid Residual=no
>> mtx: Request Sense: Error Code=70 (Current)
>> mtx: Request Sense: Sense Key=Illegal Request
>> mtx: Request Sense: FileMark=no
>> mtx: Request Sense: EOM=no
>> mtx: Request Sense: ILI=no
>> mtx: Request Sense: Additional Sense Code = 53
>> mtx: Request Sense: Additional Sense Qualifier = 03
>> mtx: Request Sense: BPV=no
>> mtx: Request Sense: Error in CDB=no
>> mtx: Request Sense: SKSV=no
>> MOVE MEDIUM from Element Address 256 to 4117 Failed
>>
>> Best Regards,
>> Stefan
>>
>>
>>     

-- 
Stefan Lubitz
System Administrator
___________________________________________________________________________
MACKEVISION
Medien Design GmbH, Stuttgart
Forststraße 7
D - 70174 Stuttgart

Tel.: +49 (0) 711/933048-0
Fax.: +49 (0) 711/933048-90

stefan.lubitz AT mackevision DOT de
www.mackevision.de

Geschäftsführer: Armin Pohl, Joachim Lincke
HRB 243735 Amtsgericht Stuttgart
Steuernummer: 99070 / 01935
USt-ID-Nr. DE 169457786


------------------------------------------------------------------------------
SF.Net email is Sponsored by MIX09, March 18-20, 2009 in Las Vegas, Nevada.
The future of the web can't happen without you.  Join us at MIX09 to help
pave the way to the Next Web now. Learn more and register at
http://ad.doubleclick.net/clk;208669438;13503038;i?http://2009.visitmix.com/
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
<Prev in Thread] Current Thread [Next in Thread>