Re: [Bacula-users] verify Volume to Catalog error
2008-05-05 08:03:12
Andreas Vidmar schrieb:
> when start a verify job
>
> Verify Volume to Catalog from a full Backup job i get the following error
>
> 05-Mai 13:24
> srzbk0001-dir:dux-verify-job-VolumeToCatalog.2008-05-05_11.23.05
> Fatal error: Networkerror with FD during Verify: ERR=Die Verbindung
> wurde vomKommunikationspartner zurÃŒckgesetzt
>
> the verify job of the incremental backup job runs fine
> any help ?
> when i run a Volume to Catalog job why is the fd daemon of the backup client
> working ?
> because the backup catalog and the volume are still on the backup server ?
The verify code is implemented in the file daemon. You can use any fd
you want in you verify job config. I use for example the fd that is
running on the director.
> complete status message
>
> 05-Mai 11:23 srzbk0001-dir:
> 05-Mai 11:23 srzbk0001-dir: 2008-mai-01
> File FileStorage
> 05-Mai 11:23 srzbk0001-dir:
> 05-Mai 11:23 srzbk0001-dir: Start Verify JobId=1232 Level=VolumeToCatalog
> Job=dux-verify-job-VolumeToCatalog.2008-05-05_11.23.05
> 05-Mai 11:23 srzbk0001-dir: Using Device "FileStorage"
> 05-Mai 11:23 srzbk0001-sd: Ready to read from volume "2008-mai-01" on device
> "FileStorage" (/data/bacula).
> 05-Mai 11:23 srzbk0001-sd: Forward spacing Volume "2008-mai-01" to file:block
> 25:3489585799.
> 05-Mai 11:31 srzbk0001-sd: End of file 34 on device "FileStorage"
> (/data/bacula), Volume "2008-mai-01"
> 05-Mai 11:31 srzbk0001-sd: End of Volume at file 34 on device "FileStorage"
> (/data/bacula), Volume "2008-mai-01"
> 05-Mai 11:31 srzbk0001-sd: End of all volumes.
> 05-Mai 13:24 srzbk0001-dir:
> dux-verify-job-VolumeToCatalog.2008-05-05_11.23.05 Fatal error: verify.c:733
> bdird<filed: bad attributes from filed n=-2 : Die Verbindung wurde vom
> Kommunikationspartner zurÃŒckgesetzt
> 05-Mai 13:24 srzbk0001-dir:
> dux-verify-job-VolumeToCatalog.2008-05-05_11.23.05 Fatal error: Network error
> with FD during Verify: ERR=Die Verbindung wurde vom Kommunikationspartner
> zurÃŒckgesetzt
This looks like thy typical 2 hour session timeout you sometimes see
with some firewalls or routers. You can set an heartbeat option in
different places. But there is an error in the verify code that may
result in other problems.
http://bugs.bacula.org/view.php?id=1061
If only the fd is behind a firewall, try running the verify job on the
director (client = srzbk0001-fd).
Ralf
-------------------------------------------------------------------------
This SF.net email is sponsored by the 2008 JavaOne(SM) Conference
Don't miss this year's exciting event. There's still time to save $100.
Use priority code J8TL2D2.
http://ad.doubleclick.net/clk;198757673;13503038;p?http://java.sun.com/javaone
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users
|
|
|