Bacula-users

Re: [Bacula-users] tape read errors

2008-04-22 19:11:16
Subject: Re: [Bacula-users] tape read errors
From: Mark Nienberg <gmane AT tippingmar DOT com>
To: bacula-users AT lists.sourceforge DOT net
Date: Tue, 22 Apr 2008 16:10:53 -0700
Mark Nienberg wrote:
> John Drescher wrote:

>> Maximum Changer Wait = time
>>     This directive specifies the maximum time in seconds for Bacula to
>> wait for an autochanger to change the volume. If this time is
>> exceeded, Bacula will invalidate the Volume slot number stored in the
>> catalog and try again. If no additional changer volumes exist, Bacula
>> will ask the operator to intervene. The default is 5 minutes.
>>
>> Maximum Rewind Wait = time
>>     This directive specifies the maximum time in seconds for Bacula to
>> wait for a rewind before timing out. If this time is exceeded, Bacula
>> will cancel the job. The default is 5 minutes.
>>
>> Maximum Open Wait = time
>>     This directive specifies the maximum time in seconds for Bacula to
>> wait for a open before timing out. If this time is exceeded, Bacula
>> will cancel the job. The default is 5 minutes.

> Increasing "Maximum Open Wait" did not fix the problem.  The timeout still 
> occurs 
> after 5 min.  I'll test "Maximum Changer Wait" next.  I think that might be 
> it.

"Maximum Changer Wait" is the correct one.  As a test, I inserted a 8 minute 
sleep 
into the mtx-changer load routine to force the issue and bacula did not timeout.

Mark


-------------------------------------------------------------------------
This SF.net email is sponsored by the 2008 JavaOne(SM) Conference 
Don't miss this year's exciting event. There's still time to save $100. 
Use priority code J8TL2D2. 
http://ad.doubleclick.net/clk;198757673;13503038;p?http://java.sun.com/javaone
_______________________________________________
Bacula-users mailing list
Bacula-users AT lists.sourceforge DOT net
https://lists.sourceforge.net/lists/listinfo/bacula-users

<Prev in Thread] Current Thread [Next in Thread>