Re: only one slot recognized
2008-11-21 14:40:17
Dustin,
Thanks. I guess it was working correctly after I added the firstslot
and lastslot parameters, but the difference from amanda 2.5.X threw me off.
This is what I get when I have only 7 tapes loaded in a 16 tape
autoloader (tapes in slots 10-16):
amtape: scanning all 16 slots in tape-changer rack:
slot 10: time X label week1tape7
slot 11: time X label week1tape6
slot 12: time X label week1tape5
slot 13: time X label week1tape4
slot 14: time X label week1tape3
slot 15: time X label week1tape2
slot 16: time X label week1tape1
slot 10: time X label week1tape7
slot 11: time X label week1tape6
slot 12: time X label week1tape5
slot 13: time X label week1tape4
slot 14: time X label week1tape3
slot 15: time X label week1tape2
slot 16: time X label week1tape1
slot 10: time X label week1tape7
slot 11: time X label week1tape6
Thanks everyone for the help.
-Nick
Dustin J. Mitchell wrote:
On Fri, Nov 21, 2008 at 7:30 AM, Nicholas Brockner
<nbrockne AT hamilton DOT edu> wrote:
So, it would appear that I need to specify firstslot in my changer.conf. BUT
when I do that, it sees 16 slots, but calls them all "slot 1" and the
changer.debug has no output:
You'll need a "lastslot", too.
178 # firstslot=? #### First storage slot (element) -- required
179 # lastslot=? #### Last storage slot (element) -- required
Dustin
|
|
|