Re: Dell PowerVault 124T issues
2006-08-12 22:16:35
Hi,
Joshua Baker-LePain wrote:
>
> Well, sg2 is the tape drive itself and sg7, like I said, is the
backplane in the server. I'm guessing that the changer is on the same
SCSI ID as the tape drive but on another LUN. Add
> 'options scsi_mod max_luns=255' to /etc/modprobe.conf, remake the
initrd, and reboot. Let us know if that helps.
>
I've modified /etc/modules.conf (since I'm still running Amanda on a RH 9)
adding the like.
By failing to communicate I understand things like this:
[root@nuts root]# mtx -f /dev/sg2 status
mtx: Request Sense: Long Report=yes
mtx: Request Sense: Valid Residual=no
mtx: Request Sense: Error Code=70 (Current)
mtx: Request Sense: Sense Key=Illegal Request
mtx: Request Sense: FileMark=no
mtx: Request Sense: EOM=no
mtx: Request Sense: ILI=no
mtx: Request Sense: Additional Sense Code = 20
mtx: Request Sense: Additional Sense Qualifier = 00
mtx: Request Sense: Field in Error = 00
mtx: Request Sense: BPV=no
mtx: Request Sense: Error in CDB=yes
mtx: Request Sense: SKSV=yes
mtx: Request Sense: Field Pointer = 00 00
READ ELEMENT STATUS Command Failed
Regards,
Iulian Topliceanu
|
|
|