ADSM-L

Re: [ADSM-L] Tape library possible replacement - push/pull

2013-01-26 07:45:59
Subject: Re: [ADSM-L] Tape library possible replacement - push/pull
From: Steven Harris <steve AT STEVENHARRIS DOT INFO>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Sat, 26 Jan 2013 23:42:56 +1100
Zoltan,

Please make your life easier by spending the small additional amount to
get ALMS.  It makes using the library so much simpler. Also for any
advanced features, such as Storage frames you will find it is required.

I'd suggest you upgrade to TS1140s while you are changing the library.
Using ALMS you can partition the library your 3592E06 (TS1130 format)
tapes are in one partition and the 3592E07 (TS1140) tapes are in
another.  This is the recommended way to deal with mixed formats.

Regards

Steve

Steven Harris
TSM Admin
Canberra Australia.

Yep, pretty much that simple.

Check the tapes out of one library, check them into another.
No more complicated than if you are going to a DR site that has a 3584 rather 
than a 3494.
TSM doesn't care.

There are some differences in the library management:

If you are talking to the 3494 library interface via TCP/IP now, that changes.  
(Some people use the TCP/IP interface, some use a serial cable.)
TSM talks to the 3584 library via the atape drive over the fibre, it has its 
own device number/path.

Thomas already mentioned that the 3584 can be partitioned into logical 
libraries.
If you have multiple TSM servers or other apps using the 3494, you keep them 
separated now by 3494 category codes, those go away.
You have the logical libraries now instead.  Carts get assigned to the logical 
libraries based on a volser range filter in the library interface.

W


-----Original Message-----
From: ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU] On Behalf Of 
Zoltan Forray
Sent: Friday, January 25, 2013 2:08 PM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: [ADSM-L] Tape library possible replacement - push/pull

We are starting to examine the idea of replacing our aging 3494 (installed
1995) due to difficulty in getting parts and having more frequent outages due 
to robot issues.

Since we have 17-TS1130 drives, the natural transition would be to a 
TS3500/3584.

If we go down this route, one issue might be the floorspace/placement,  which 
might require a weekend eject-push-pull-reload.

Never having dealt with any tape library other than the 3494, I am trying to 
collect as much info as I can on doing a swap-out.

Is it as simple as defining the new library, moving the drives/paths to it,  
changing the devclass to point to the new library, checkin everything 
(scratch/private)??  Am I missing anything?

--
*Zoltan Forray*
TSM Software & Hardware Administrator
Virginia Commonwealth University
UCC/Office of Technology Services
zforray AT vcu DOT edu - 804-828-4807
Don't be a phishing victim - VCU and other reputable organizations will never 
use email to request that you reply with your password, social security number 
or confidential personal information. For more details visit 
http://infosecurity.vcu.edu/phishing.html