ADSM-L

Re: [ADSM-L] Drive and Path Definition

2012-01-18 16:33:59
Subject: Re: [ADSM-L] Drive and Path Definition
From: Shawn Drew <shawn.drew AT AMERICAS.BNPPARIBAS DOT COM>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Wed, 18 Jan 2012 10:43:25 -0500
You did the itdt against rmt0, but you are defining the path to rmt11. I'm 
assuming this is happening for all drive and that discrepancy doesn't 
actually mean anything. 

The problem is most likely with the library device smcX, not the drives. 
- I can't remember the commands, but can you probe the library device with 
itdt?  I think its smc0 with atape.
- is Drive 11 actually in library "kvtl1p1"?
- is the path to the library device for kvtl1p1 is already defined and 
online?
- Was this drive a recent addition to the library? 
- If so, was the TSM instance restarted since it was added? (restarting 
the instance will repprobe the library for new elements, drives/slots, 
etc)
- Are all drives in the library not working or only drive 11?



Regards, 
Shawn
________________________________________________
Shawn Drew





Internet
mctailor AT CARILIONCLINIC DOT ORG

Sent by: ADSM-L AT VM.MARIST DOT EDU
01/18/2012 09:41 AM
Please respond to
ADSM-L AT VM.MARIST DOT EDU


To
ADSM-L
cc

Subject
[ADSM-L] Drive and Path Definition






Hello.

I have a PMR on this, but not making much progress on it so thought I 
would send this out on the User List to see if anyone else encountered 
this issue and can suggest a fix.

Here's what I have:

TSM 6.2.3.100
AIX 7.1 (oslevel: 7100-00-04-1140)
IBM FC 5729 8-Gbps FC adapters

SAN Switch: IBM SAN-768A (Brocade DCX)

Atape 12.1.5.0
Sepaton VTL emulating 3584L22 and 3592 tape drives
SANDISCOVERY ON

We define a tape drive on the VTL and present it to the TSM server.  AIX 
discovers the tape drive and I can use itdt (tapeutil) to query the drive. 
 For example...

./itdt -f /dev/rmt0 inquiry
Issuing std inquiry...
Inquiry Data,  Length 96
            0 1  2 3  4 5  6 7  8 9  A B  C D  E F   0123456789ABCDEF
    0000 - 0180 0302 3300 1130 4942 4D20 2020 2020  [.�..3..0IBM     ]
    0010 - 3033 3539 324A 3141 2020 2020 2020 2020  [03592J1A        ]
    0020 - 3035 3039 3638 3030 5347 3131 3032 3330  [05096800SG110230]
    0030 - 3031 2030 0500 0181 0000 0000 0000 0000  [01 0...�........]
    0040 - 0000 0000 0000 0000 0000 0000 0000 0000  [................]
    0050 - 0000 0000 0000 0000 0000 0000 0000 0000  [................]

Exit with code: 0
./itdt -f /dev/rmt0 inquiry 80
Issuing inquiry for page 0x80...
Inquiry Page 0x80,  Length 14
            0 1  2 3  4 5  6 7  8 9  A B  C D  E F   0123456789ABCDEF
    0000 - 0180 000A 5347 3131 3032 3330 3031       [.�..SG11023001  ]

Exit with code: 0

I log into TSM and define the drive.

01/17/12   11:55:36      ANR2017I Administrator ADMIN issued command: 
DEFINE DRIVE
                          kvtl1p1 rmt11 serial=autod elem=autod  (SESSION: 
15)
01/17/12   11:55:36      ANR8404I Drive RMT11 defined in library KVTL1P1. 
(SESSION:
                          15)

Then I try to define the path.

01/17/12   11:56:16      ANR2017I Administrator ADMIN issued command: 
DEFINE PATH
                          tsmprd01 rmt11 srct=server destt=drive autod=yes
                          devi=/dev/rmt11 library=kvtl1p1 online=yes 
(SESSION: 15)
01/17/12   11:56:16      ANR8972E DEFINE PATH: Unable to find the element 
number
                          for drive RMT11 in library KVTL1P1.  (SESSION: 
15)
I stop and restart TSM and issue the same command.

01/17/12   12:00:00      ANR2017I Administrator ADMIN issued command: 
DEFINE PATH
                          tsmprd01 rmt11 srct=server destt=drive autod=yes
                          devi=/dev/rmt11 library=kvtl1p1 online=yes 
(SESSION: 1)
01/17/12   12:00:00      ANR8955I Drive RMT11 in library KVTL1P1 with 
serial number
                           is updated with the newly discovered serial 
number
                          SG11023012. (SESSION: 1)
01/17/12   12:00:00      ANR1720I A path from TSMPRD01 to KVTL1P1 RMT11 
has been
                          defined. (SESSION: 1)
Has anyone else seen this problem?  Any ideas?

TIA

Mahesh

________________________________
Notice: The information and attachment(s) contained in this communication 
are intended for the addressee only, and may be confidential and/or 
legally privileged. If you have received this communication in error, 
please contact the sender immediately, and delete this communication from 
any computer or network system. Any interception, review, printing, 
copying, re-transmission, dissemination, or other use of, or taking of any 
action upon this information by persons or entities other than the 
intended recipient is strictly prohibited by law and may subject them to 
criminal or civil liability. Carilion Clinic shall not be liable for the 
improper and/or incomplete transmission of the information contained in 
this communication or for any delay in its receipt.




This message and any attachments (the "message") is intended solely for 
the addressees and is confidential. If you receive this message in error, 
please delete it and immediately notify the sender. Any use not in accord 
with its purpose, any dissemination or disclosure, either whole or partial, 
is prohibited except formal approval. The internet can not guarantee the 
integrity of this message. BNP PARIBAS (and its subsidiaries) shall (will) 
not therefore be liable for the message if modified. Please note that certain 
functions and services for BNP Paribas may be performed by BNP Paribas RCC, Inc.