Hi All
I have 3 copy pools on my TSM server.
One for normal type retention, one for monthly, and one for yearly.
The though process behind it was that similar type retention data i.e
monthly schedules are moved to monthly copy pools etc.
Am iwrong in doing this.
If I keep them all in one copy poll, is this better, and are there
performance/amount of tapes used issues that I will experience.
I find my offsite's create process are taking forever. I use a TS3310
Tape Library with 6 LTO3 FC drives, on TSm 5.5.4 on AIX 5.3 IBMp570
LPAR.
We have also not split FC tape data and SAN traffic and both are over
the same HBA.
Thanks in advance.
tsm: TSM-PLZ>q stg
Storage Device Estimated Pct Pct High
Low Next Stora-
Pool Name Class Name Capacity Util Migr Mig
Mig ge Pool
Pct
Pct
----------- ---------- ---------- ----- ----- ----
--- -----------
ARCHPOOL LTO3310DE- 7,089 G 3.0 40.0 90
70
VCL
DISKPOOL DISK 1,501 G 66.1 66.1 98
70 OVERFLOW
DISKPOOL1 DISK 1,500 G 85.2 85.2 98
70 OVERFLOW
INFORMIXMO- LTO3310DE- 26,084 G 9.7 15.0 90
70
NTH VCL
INFORMIXUN- LTO3310DE- 0.0 M 0.0 0.0 90
70
LIMITED VCL
INFORMIXWE- LTO3310DE- 90,061 G 17.4 24.0 90
70
EKLY VCL
INFORMIXYE- LTO3310DE- 8,192 G 3.1 10.0 90
70
ARLY VCL
LEGACY LTO3310DE- 0.0 M 0.0 0.0 90
70
VCL
MONTHPOOL LTO3310DE- 28,750 G 42.8 56.0 90
70
VCL
OFFSITE_33- LTO3310DE- 308,130 G 17.9
10 VCL
OFFSITE_MO- LTO3310DE- 70,410 G 21.1
NTHLY VCL
OFFSITE_YE- LTO3310DE- 81,920 G 0.5
ARLY VCL
OVERFLOW LTO3310DE- 73,675 G 20.2 28.0 90
70
VCL
TAPEPOOL LTO3310DE- 111,220 G 21.7 32.5 90
70
VCL
YEARPOOL LTO3310DE- 16,384 G 0.7 5.0 90
70
VCL
Regards
Adrian Compton
Group IT Infrastructure
Pharmacare Limited trading as Aspen Pharmacare
P O Box 4002
Korsten
Port Elizabeth
6014
Switchboard Tel No: +27 (0) 41 407 2111
Tel No: +27 (0) 41 407 2855
Fax: +27 (0) 41 453 7452
Cell: +27 (0) 82 861 7745
No trees were killed in the sending of this message.
However, many electrons were terribly inconvenienced.
Email : acompton AT aspenpharma DOT com This email is solely for the named
addressee. Any unauthorised use or interception of this email, or the
review, retransmission, dissemination or other use of, or taking of any
action in reliance upon the contents of this email, by persons or
entities other than the intended recipient, is prohibited. If you are
not the named addressee please notify us immediately by way of a reply
e-mail, and also delete this email and any attached files.
Disclaimer: You must scan this email and any attached files for viruses
and/or any other defects. Pharmacare Limited accepts no liability for
any loss, damages or consequence, whether direct, indirect,
consequential or economic, however caused, and whether by negligence or
otherwise, which may result directly or indirectly from this
communication or of any attached files.
|