I'm not really sure what to make of the failures i'm seeing when doing
an import. Specifically i'm not sure how to obtain more information
about the failure showing up in errpt. Appreciate any help/direction
on how to interpret the sense data.
root@bs-ip51a-23-030:/$ lsdev -C | grep mt
mt0 Available 02-08-00-1,0 Tivoli Storage Manager Tape Drive
mt1 Available 02-08-00-2,0 Tivoli Storage Manager Tape Drive
mt2 Available 02-08-00-3,0 Tivoli Storage Manager Tape Drive
mt3 Available 02-08-01-4,0 Tivoli Storage Manager Tape Drive
mt4 Available 02-08-01-5,0 Tivoli Storage Manager Tape Drive
mt5 Available 02-08-01-6,0 Tivoli Storage Manager Tape Drive
rmt0 Available 00-09-00-0,0 IBM 3580 Ultrium Tape Drive
rmt1 Available 02-08-00-1,0 Other SCSI Tape Drive
rmt2 Available 02-08-00-2,0 Other SCSI Tape Drive
rmt3 Available 02-08-00-3,0 Other SCSI Tape Drive
rmt4 Available 02-08-01-4,0 Other SCSI Tape Drive
rmt5 Available 02-08-01-5,0 Other SCSI Tape Drive
rmt6 Available 02-08-01-6,0 Other SCSI Tape Drive
root@bs-ip51a-23-030:/$ errpt | head
IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION
5680E405 0721004607 P H mt5 STORAGE SUBSYSTEM FAILURE
5680E405 0720193407 P H mt0 STORAGE SUBSYSTEM FAILURE
5680E405 0717162007 P H mt0 STORAGE SUBSYSTEM FAILURE
5680E405 0717144007 P H mt0 STORAGE SUBSYSTEM FAILURE
5680E405 0716104507 P H mt0 STORAGE SUBSYSTEM FAILURE
5680E405 0715114807 P H mt1 STORAGE SUBSYSTEM FAILURE
4865FA9B 0714195507 P H rmt0 TAPE OPERATION ERROR
DE9A52D1 0714195507 I S rmt0 DEVICE DUMP RETRIEVED
0BA49C99 0714161107 T H scsi2 SCSI BUS ERROR
root@bs-ip51a-23-030:/$
root@bs-ip51a-23-030:/$ errpt -aj 5680E405 | more
---------------------------------------------------------------------------
LABEL: ADSM_DD_LOG2
IDENTIFIER: 5680E405
Date/Time: Sat Jul 21 00:46:53 PDT 2007
Sequence Number: 106
Machine Id: 00CB5C1E4C00
Node Id: bs-ip51a-23-030
Class: H
Type: PERM
Resource Name: mt5
Resource Class: adsmtape
Resource Type: ADSM-SCSI-MT
Location: U788C.001.AAA9117-P1-C13-C1-T2-L6-L0
Description
STORAGE SUBSYSTEM FAILURE
Probable Causes
ATTACHED SCSI TARGET DEVICE
SCSI ADAPTER
Failure Causes
ATTACHED SCSI TARGET DEVICE
SCSI ADAPTER
Recommended Actions
RUN DIAGNOSTICS AGAINST THE FAILING DEVICE
CHECK PHYSICAL INSTALLATION
CHECK FOR CORRECT MICROCODE FIX
CONTACT APPROPRIATE SERVICE REPRESENTATIVE
Detail Data
COMMAND
0606 0000 0800 007F F800 0000 0000 0000
STATUS CODE
0000 0000
SENSE DATA
0102 0000 F000 0300 007F F81E 0000 0000 1100 0000 009D 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
ERROR CODE
0
RETURN CODE
0
REFERENCE CODE
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000
|