ADSM-L

3584 library not initialized because of faulty drive ...

2005-11-08 09:49:36
Subject: 3584 library not initialized because of faulty drive ...
From: PAC Brion Arnaud <Arnaud.Brion AT PANALPINA DOT COM>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Tue, 8 Nov 2005 15:49:10 +0100
Hi list,
 
I had a problem this morning, where I lost one of the LTO1 drives of our
3584 library. I then opened a call by IBM, and like always, their first
advice was to upgrade the Atape driver to latest version (9.6.0.0) and
to delete/redefine the drive at AIX (5.3.0) level. I followed their
recommendations, to no success, as it was in fact due to some faulty
Fiber connection, what I discovered later ...
Off course, to perform the Atape driver upgrade, I had to stop TSM
server, thus avoiding any eventual tape access ... My problem appeared
when I tried to restart the server, under the form of this message in
activity log :

11/08/05 12:26:15     ANR8963E Unable to find path to match the serial
number   
                       defined for drive LTO1DR6 in library LTOLIB1 .

11/08/05 12:26:16     ANR9999D mmsscsi.c(7771): ThreadId<18> Unable to
restore  
                       library drive state for LTOLIB1.

11/08/05 12:26:16     ANR9999D ThreadId<18> issued message 9999 from:

                       <-0x000000010001bf88 outDiagf
<-0x00000001005b87d8       
                       PerformInit <-0x00000001005b89e0 InitThread
<-0x00000001 
                       0000e958 StartThread <-0x09000000005412dc
_pthread_body  
11/08/05 12:26:16     ANR8440E Initialization failed for SCSI library
LTOLIB1;  
                       will retry in 2 minute(s).

I had to remove the path and drive definitions for the faulty drive, to
finally get the whole library initialized ! This seems very strange to
me, as, AFAIR, I've never seen such a behavior ...
We upgraded recently to TSM 5.3.1.4 : is it a new "function" which was
introduced at this level ? 
Anyway, I find it pretty strange that a whole library could not be
initialized just because of one missing drive...
Anybody having an explanation ?
TIA.
Cheers.

Arnaud

************************************************************************
******
Panalpina Management Ltd., Basle, Switzerland,
CIT Department Viadukstrasse 42, P.O. Box 4002 Basel/CH
Phone:  +41 (61) 226 11 11, FAX: +41 (61) 226 17 01
Direct: +41 (61) 226 19 78
e-mail: arnaud.brion AT panalpina DOT com
************************************************************************
******

<Prev in Thread] Current Thread [Next in Thread>
  • 3584 library not initialized because of faulty drive ..., PAC Brion Arnaud <=