ADSM-L

Re: ANR8311E Error -What does FLUSH operation mean?

2004-12-17 15:51:40
Subject: Re: ANR8311E Error -What does FLUSH operation mean?
From: Nancy L Backhaus <Backhaus.Nancy AT HEALTHNOW DOT ORG>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Fri, 17 Dec 2004 15:41:21 -0500
We have already switched the scsi cables, but I can re-visit it again. The
vendor looks at the drive snapshots..when the error occurs..and everything
looks fine on their end.



Nancy Backhaus
Enterprise Systems
Backhaus.Nancy AT HealthNow DOT org
Office: (716) 887-7979
Cell: (716)  609-2138




Richard Sims <rbs AT BU DOT EDU>
Sent by: "ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU>
12/17/2004 03:21 PM
Please respond to "ADSM: Dist Stor Manager"


        To:     ADSM-L AT VM.MARIST DOT EDU
        cc:
        Subject:        Re: ANR8311E  Error -What does FLUSH operation mean?


Nancy - A Flush operation refers to writing to tape all the data
         which the tape drive has buffered...a sync operation.
Sounds like you have a drive problem.  But I've experienced what
seem to be drive problems when the actual problem was a cable
or SCSI terminator.  (We had what looked like a drive problem
for about a year: switching the terminator caused the problem to
go away.  Lesson: never overlook trivial causes.)

    Richard Sims




CONFIDENTIALITY NOTICE: This email message and any attachments are for the sole 
use of the intended recipient(s) and may contain proprietary, confidential, 
trade secret or privileged information.  Any unauthorized review, use, 
disclosure or distribution is prohibited and may be a violation of law.  If you 
are not the intended recipient or a person responsible for delivering this 
message to an intended recipient, please contact the sender by reply email and 
destroy all copies of the original
message.

<Prev in Thread] Current Thread [Next in Thread>