ADSM-L

Re: Element addresses for new scsi LTO drive

2004-03-30 18:38:07
Subject: Re: Element addresses for new scsi LTO drive
From: CORP Rick Willmore <RWillmore AT RSAC DOT COM>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Tue, 30 Mar 2004 15:37:45 -0800
Just FYI to everyone

I restarted my TSM server and I was able to add the path and drive that I was 
having so much difficulty with.. 
ADSM = Windows???  Thanks for all the assistance people.

R

-----Original Message-----
From: Orville Lantto [mailto:orville.lantto AT DATATREND DOT COM]
Sent: Monday, March 29, 2004 3:08 PM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: Element addresses for new scsi LTO drive


Have you registered the license for Managed Libraries?  The base product
only has license for two drives.

Orville L. Lantto
Datatrend Technologies, Inc.  (http://www.datatrend.com)
IBM Premier Business Partner
121 Cheshire Lane, Suite 700
Minnetonka, MN 55305
Email: Orville.Lantto AT datatrend DOT com


CONFIDENTIALITY NOTICE: This e-mail message, including any attachments, is
for the sole use of the intended recipient(s) and may contain confidential
and privileged information. Any  unauthorized review, use, disclosure or
distribution is prohibited. If you are not the intended recipient, please
contact the sender by reply e-mail and destroy all copies of the original
message.




CORP Rick Willmore <RWillmore AT RSAC DOT COM>
Sent by: "ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU>
03/29/2004 04:53 PM
Please respond to "ADSM: Dist Stor Manager"

        To:     ADSM-L AT VM.MARIST DOT EDU
        cc:
        Subject:        Re: Element addresses for new scsi LTO drive


I just removed and tried to readd .. I was able to add drive 1 and drive 2
as address 256 and 257 with no problem.  The instant I tried drive3 for
258 it failed.  BTW as for syntax errors I am using the web interface.

R.

-----Original Message-----
From: Linda Zgonce [mailto:lindazg AT US.IBM DOT COM]
Sent: Monday, March 29, 2004 2:05 PM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: Element addresses for new scsi LTO drive






Define it as drive 3, not drive 1. You have a syntax error.

Regards,

  Linda Zgonce
    IBM Global Services South




                      CORP Rick
                      Willmore                 To: ADSM-L AT VM.MARIST DOT EDU
                      <[email protected]        cc:
                      OM>                      Subject:  Re: Element
addresses for new scsi LTO drive
                      Sent by: "ADSM:
                      Dist Stor
                      Manager"
                      <[email protected]
                      .EDU>


                      03/29/2004 12:43
                      PM
                      Please respond to
                      "ADSM: Dist Stor
                      Manager"





tsm: TSM>define drive autolib drive1 online=yes element=258
cleanfreq=asneeded
ANR8366E DEFINE DRIVE: Invalid value for ELEMENT parameter.
ANS8001I Return code 3.

Same error.

R.

-----Original Message-----
From: Linda Zgonce [mailto:lindazg AT US.IBM DOT COM]
Sent: Monday, March 29, 2004 6:16 AM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: Element addresses for new scsi LTO drive







You have a syntax error in your ITSM define drive command. Try this :

tsm: TSM>define drive autolib drive3 online=yes element=258
cleanfreq=asneeded


Regards,

  Linda Zgonce
  IBM Global Services South -ITSM




                      CORP Rick
                      Willmore                 To:
ADSM-L AT VM.MARIST DOT EDU
                      <[email protected]        cc:
                      OM>                      Subject:  Element addresses
for new scsi LTO drive
                      Sent by: "ADSM:
                      Dist Stor
                      Manager"
                      <[email protected]
                      .EDU>


                      03/26/2004 01:19
                      PM
                      Please respond to
                      "ADSM: Dist Stor
                      Manager"





Hey all,
I noticed that others of the list seem to have similar element address
problems but I didnt see my solution so I was hoping to throw this one out
and see what sticks.

I just added a new LTO (ver1) drive to our Scalar 100 Library.  I used
lbtest and can see the element address reported by the new drive is 258
(the 2 previous drives are 256 and 257).  When I try to move the media to
the 258 address or define the new drive to tsm I receive an error.

hal> lsdev -Cc tape
rmt0 Available 2A-09-00-3,0 LTO Ultrium Tape Drive
rmt1 Available 2A-09-00-4,0 LTO Ultrium Tape Drive
rmt2 Available 2A-09-00-2,0 LTO Ultrium Tape Drive   <-- new drive

enter selection: 8
Library Element Count:
  compcode                   = 0
  number of drives           = 3
  number of storage slots    = 42
  number of transport elem   = 1
  number of entry exit ports = 12
analyze rc 0  err 0 (Successful,Error 0)
    cc 0 (Successful) resid 0 data 0
Total elapsed time in seconds =     3.00


Library Inventory:
Drive 1 (address 256 EMPTY)
  abnormal_state = 0,  accessible = 1, scsi_bus_not_pres = 0,
  scsi_bus_id_flag = 1, scsi_bus_id = 3, lun_flag = 0,
  lun = 0, source_addr_flag = 0, source_elem_addr = 0,
  invert_media_flag = 0, barcode_flag = 1, barcode_len = 36
Drive 2 (address 257 EMPTY)
  abnormal_state = 0,  accessible = 1, scsi_bus_not_pres = 0,
  scsi_bus_id_flag = 1, scsi_bus_id = 4, lun_flag = 0,
  lun = 0, source_addr_flag = 0, source_elem_addr = 0,
  invert_media_flag = 0, barcode_flag = 1, barcode_len = 36
Drive 3 (address 258 EMPTY)
  abnormal_state = 0,  accessible = 1, scsi_bus_not_pres = 0,
  scsi_bus_id_flag = 1, scsi_bus_id = 2, lun_flag = 0,
  lun = 0, source_addr_flag = 0, source_elem_addr = 0,
  invert_media_flag = 0, barcode_flag = 1, barcode_len = 36


enter selection: 11
transport element address: 1
source address moving from: 11
destination address moving to: 258
invert option:  (1) invert (0) not invert:
execute move_medium taddr = 1 saddr = 11 daddr = 258 invert = 0
analyze rc -1  err 22 (EINVAL,Invalid argument)
    cc 0 (Successful) resid 0 data 0
error_state last_status 22 (EINVAL) last_compcode 207 (DD_ILLEGAL_REQUEST)
  information 0 number_sense 18
Sense KEY/ASC/ASCQ =  5/21/ 1
      KEY meaning is illegal request
      ASC/ASCQ meaning is invalid element address
sense bytes 000-015: 70  0  5  0  0  0  0  a  0  0  0  0 21  1  0 c0
sense bytes 016-031:  0  4
analyze return_error cc 207 (DD_ILLEGAL_REQUEST)
analyze conclusion ...  ERROR not as expected
ERROR, test failed!
Total elapsed time in seconds =     7.00
Return to continue:

tsm: TSM>define drive autolib drive1 online=yes element=258
cleanfreq=asneeded
ANR8366E DEFINE DRIVE: Invalid value for ELEMENT parameter.
ANS8001I Return code 3.


Any help is appreciated.

Rick.