ADSM-L

Re: data move question

2004-02-14 18:35:49
Subject: Re: data move question
From: "Hooft, Jeroen" <Jeroen.Hooft AT ATOSORIGIN DOT COM>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Sat, 14 Feb 2004 20:25:23 +0100
If you don't have a copypool and you have enough space on a diskpool,
you can bring the problematic drive offline and move the data to the
diskpool.

If you lack the diskspace you can define an extra device-class and
library for the same physical library. Add the problematic drive to the
new library, define a primary tape-storagepool on the new device-class
and then issue the "move data ITG017L2 stg=NEW_STG".

Jeroen


-----Original Message-----
From: Stapleton, Mark [mailto:stapleto AT BERBEE DOT COM] 
Sent: 14 February 2004 18:26
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Re: data move question


Read a little more carefully, David. Alexander only has two drives. He
can't take one of them offline and do a move data.
 
Try a restore volume, Alexander. I assume you have a copy tape pool for
such use.
 
--
Mark Stapleton (stapleton AT berbee DOT com)

        -----Original Message----- 
        From: David E Ehresman [mailto:deehre01 AT LOUISVILLE DOT EDU] 
        Sent: Fri 2/13/2004 13:58 
        To: ADSM-L AT VM.MARIST DOT EDU 
        Cc: 
        Subject: Re: data move question
        
        

        Leave MT1.0.0.3 offline and reissued the move data.  It will
then have
        to pick another drive to try the mount.
        
        >>> alazarev AT ITG.UIUC DOT EDU 2/13/2004 2:14:14 PM >>>
        TSM 5.1.6.5 server on windows 2K server SP4. Adaptec 29160
controller.
        Overland Neo 4100 with 2 X LTO-2 SCSI drives. 31 LTO2 tapes.
        
        One of our drives, MT1.0.0.3, keeps going offline with the
following
        error:
        
        02/13/2004 12:00:39  ANR8944E Hardware or media error on drive
        MT1.0.0.3
                             (mt1.0.0.3) (OP=READ, Error Number=1117,
CC=305,
                             KEY=04, ASC=44, ASCQ=00,
                             SENSE=F0.00.04.00.00.24.47.0E.00.00.00.-
                             00.44.00.00.00.30.20.00.00.00.00.,
        Description=Drive
                             failure).  Refer to Appendix D in the
'Messages'
                             manual for recommended action.
        
        One particular tape keeps making the drive fail - ITG017L2. When
I
        move
        data off that tape, the server ALWAYS mounts that tape into
MT1.0.0.3.
        The drive then fails with the error above and the drive is
marked as
        offline. Yet the tape reports no read or write errors. So I'm
not sure
        where the problem lies: tape or drive.
        
        I have a suspicion it is the tape, what I need to do is force
tape
        ITG017L2 into the other drive, MT2.0.0.3, and try moving the
data from
        that other drive. If MT2.0.0.3 fails the same way, then I'm
almost
        certain
        it's a bad tape.
        
        Is there a way to force the server to put tape ITG017L2 into
drive
        MT2.0.0.3 for a move data?
        
        Thanks in advance,
        
        Alex
        