Hi folks,
I4m having the following problem:
My TSM Server is a W2k (SP4).
The TSM Server is 5.1.0.0. In Device Manager (Windows) the drivers installed
are:
- IBM Magstar 3590 media charger - version 5.0.6.7
- IBM 03590E11 SCSI Sequential Device - version 5.0.6.7
I have two machines. One online and another for tests. The drivers installed
are the same (Windows), and the magstar is the same (3590, the same equipment).
When I did my upgrade (test machine), I4ve been a problem in checkin.
when I did the command:
checkin libv <library> search=yes status=private/scratch
it takes the tape without problems (not into the bulk).
but, when I did the following command:
checkin libv <library> search=bulk status=private/scratch
it NOT takes the tape inside the bulk.
When I see the actlog, it informes me that:
01/19/2004 15:05:44 ANR8302E I/O error on drive MT1.0.0.1 (MT1.0.0.1)
(OP=TESTREADY, Error Number=21, CC=0, KEY=02, ASC=3A,
ASCQ=00, SENSE=70.00.02.00.00.00.00.58.00.00.00.00.3A.00-
.FF.0A.C4.08.01.01.00.06.01.40.00.00.00.00.00.00.01.00.0-
0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.-
00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00-
.00.00.33.35.30.20.20.20.20.00.00.00.00.00.00.00.00.00.0-
0.00.00.00.00.00.00.00, Description=An undetermined error
has occurred). Refer to Appendix D in the 'Messages'
manual for recommended action.
01/19/2004 15:05:44 ANR8304E Time out error on drive MT1.0.0.1 (MT1.0.0.1) in
library LB1.1.0.1.
01/19/2004 15:05:44 ANR8912E Unable to verify the label of volume from
slot-element 31 in drive MT1.0.0.1 (MT1.0.0.1) in library
LB1.1.0.1.
01/19/2004 15:05:44 ANR8302E I/O error on drive MT1.0.0.1 (MT1.0.0.1)
(OP=OFFL, Error Number=21, CC=0, KEY=02, ASC=3A, ASCQ=00,
SENSE=70.00.02.00.00.00.00.58.00.00.00.00.3A.00.FF.0A.C9-
.0B.01.01.00.06.01.40.00.00.00.00.00.00.1B.00.00.00.00.0-
0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.-
00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.33-
.35.30.20.20.20.20.00.00.00.00.00.00.00.00.00.00.00.00.0-
0.00.00.00.00, Description=An undetermined error has
occurred). Refer to Appendix D in the 'Messages' manual
for recommended action.
01/19/2004 15:05:44 ANR8942E Could not move volume NOT KNOWN from slot-element
16 to slot-element 31.
01/19/2004 15:05:44 ANR8832E CHECKIN LIBVOLUME for volumes in search mode in
library LB1.1.0.1 failed.
I made a phone call to IBM and they said me that the possible solution it will
be change de microcode level of 3590. Sincerely, I disagree this can be resolve
my problem, because in tsm 5.1, this procedure is running online e ok !!! (so,
i didn4t do my upgrade yet), and the library/drive are the same (I just
unplugged from my online machine to my test machine).
In my online machine I have two libraries, so to prove this I made the same
test with both libraries (I turned off my online server and connect the
libraries in my test machine), and the same problem happened (it4s impossible
two libraries have the same problem - hardware !!!)
I don4t have any idea what to do !!!
anyone could help me ?
thanks
George
---------------------------------
Yahoo! GeoCities: a maneira mais facil de criar seu web site gratis!
|