You can do a reinventory of a 3494 with little problem. It will just scan
each barcode in the library, and it will continue to do other operations,
like mounts & dismounts, while it is going to reinventory.
I have a 12 frame library, and that takes between 10-30 minutes depending on
what else is going on with the library.
------------------------------------
David N. Reiss 407-736-3912
TSM Support Engineer
david.reiss AT siemens DOT com
...one of God's own prototypes -- a high-powered mutant of some kind who was
never even considered for mass production. He was too weird to live and too
rare to die.
-----Original Message-----
From: Mike Cantrell [mailto:Mike_Cantrell AT SAKSINC DOT COM]
Sent: Monday, August 11, 2003 12:25 PM
To: ADSM-L AT VM.MARIST DOT EDU
Subject: Need to remove 3494 tape from library
Hello
I have an erroneous tape reference in my 3494 library. The vol serial number
is 400699 I have tried mtlib -l /dev/lmcp0 -C -t FF10 -V 400699 and get
ther error Change Category operation Failed, ERPA code - 7B, Library
Volume Manually Ejected. When I run mtlib -l /dev/lmcp0 -q I and grep 400699
the refernecr is still their. I notice that there is an option to audit
the library from the library console, but not having done this I am somewhat
hesitate to try and just see what happens. Any Ideas?
Thanks
Mike Cantrell
|