ADSM-L

lan-free tape dismount retention

2003-07-16 09:08:28
Subject: lan-free tape dismount retention
From: Joni Moyer <joni.moyer AT HIGHMARK DOT COM>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Wed, 16 Jul 2003 09:07:57 -0400
Hello!

I'm working on the TPOC right now and I have the mount retention set to
9999 minutes, but as you can see below the volumes is being dismounted
seconds after the archive session to the tape drive has completed for the
storage agent.  Is there a parameter that must be set on the storage agent?
Or do I need to change something under the TSM server configuration.
Thanks!

07/16/03 08:45:02     ANR0403I Session 421 ended for node PGSU017 (SUN
SOLARIS).
07/16/03 08:46:00     ANR8325I (Session: 249, Origin: STORAGENT)
Dismounting
                       volume 331ABJ - 1 minute mount retention expired.

07/16/03 08:46:05     ANR8336I (Session: 249, Origin: STORAGENT)  Verifying

                       label of LTO volume 331ABJ in drive LTO2_DRIVE-1

                       (/dev/rmt/2st).

07/16/03 08:47:17     ANR0408I Session 427 started for server STORAGENT
(Solaris
                       2.6/7/8 ) (Tcp/Ip) for library sharing.

07/16/03 08:47:17     ANR8336I Verifying label of LTO volume 331ABJ in
drive
                       LTO2_DRIVE-1 (/dev/rmt/3st).
07/16/03 08:47:17     ANR8468I (Session: 249, Origin: STORAGENT)  LTO
volume
                       331ABJ dismounted from drive LTO2_DRIVE-1
(/dev/rmt/2st)
                       in library 3584_LTO2.


Here is the device class that the data was going to:
             Device Class Name: DEVCLASS_LTO2
        Device Access Strategy: Sequential
            Storage Pool Count: 1
                   Device Type: LTO
                        Format: ULTRIUM2
         Est/Max Capacity (MB): 409,600.0
                   Mount Limit: 2
              Mount Wait (min): 60
         Mount Retention (min): 9,999
                  Label Prefix: ADSM
                       Library: 3584_LTO2
                     Directory:
                   Server Name:
                  Retry Period:
                Retry Interval:
                        Shared:

Joni Moyer
Systems Programmer
joni.moyer AT highmark DOT com
(717)975-8338