ADSM-L

ANR8944E Hardware or media error on drive

2003-06-12 04:26:18
Subject: ANR8944E Hardware or media error on drive
From: Klaas Talsma - KTL <KTalsma AT BELLMICRO.EU DOT COM>
To: ADSM-L AT VM.MARIST DOT EDU
Date: Thu, 12 Jun 2003 09:10:00 +0100
Hi

I've got the following problem.
The following shows up in the activity log:

ANR8944E Hardware or media error on drive DRIVE1          
                       (mt2.0.0.2) (OP=LOCATE, Error Number=23, CC=0, KEY=03,   
                       ASC=14, ASCQ=00, SENSE=70.00.03.00.00.00.00.1C.00.00.00.-
                       00.14.00.07.00.20.84.FF.FF.00.03.20.20.20.20.20.20.20.0D-
                       .00.00.1C.A7.02.00.00.00.00.00.00.00.00.00.00.00.00.00.0-
                       0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.-
                       00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00-
                       .00.00.00.00.00.00.00.00.00.00, Description=An           
                       undetermined error has occurred).  Refer to Appendix D in
                       the 'Messages' manual for recommended action.            
11-06-2003 07:59:14   ANR8359E Media fault detected on LTO volume 000765L1 in   
                       drive DRIVE1 (mt2.0.0.2) of library 3583LIB.             
11-06-2003 08:01:14   ANR8944E Hardware or media error on drive DRIVE1          
                       (mt2.0.0.2) (OP=LOCATE, Error Number=23, CC=0, KEY=03,   
                       ASC=14, ASCQ=00, 

And repeats itself, same drive same volume.
If this was a scratch volume then i think there is a solution for it because 
i've read something about TSM still trying to use a scratch tape with media 
faults because it cannot mark scratch tapes damaged.
Problem here is that is is a tape with data (q libv status) and i'm not sure 
how to fix this problem.

Can anyone shed some light on this?

Thanks in advance,

Klaas Talsma


--
Bell Microproducts Europe BV

This message is intended only for the use of the person(s) (\"the intended 
recipient(s)\") to whom it is addressed.  It may contain information which is 
privileged and confidential within the meaning of applicable law.  If you are 
not the intended recipient, please contact the sender as soon as possible.  The 
views expressed in this communication may not necessarily be the views held by 
Bell Microproducts Europe BV.

<Prev in Thread] Current Thread [Next in Thread>