ADSM-L

Label new 3590 cartridge

2002-07-12 09:35:40
Subject: Label new 3590 cartridge
From: "Rupp Thomas (Illwerke)" <thomas.rupp AT ILLWERKE DOT AT>
Date: Fri, 12 Jul 2002 15:32:31 +0200
Dear (I)*SM-ers,

a defect 3590 extended length cartridge was replaces by IBM.
When I try to label this cartridge for our 3494 library with
"LABEL libvolume lib3494 010251 checkin=scratch devtype=3590" I get the
following errors:

07/11/02 17:23:48 ANR2017I Administrator SYSA issued command: LABEL
libvolume lib3494 010251 checkin=scratch devtype=3590
07/11/02 17:23:48 ANR0984I Process 16 for LABEL LIBVOLUME started in the
BACKGROUND at 17:23:48.
07/11/02 17:23:48 ANR8799I LABEL LIBVOLUME: Operation for library LIB3494
started as process 16.
07/11/02 17:23:48 ANR0609I LABEL LIBVOLUME started as process 16.
07/11/02 17:31:44 ANR8302E I/O error on drive DRIVE2 (/dev/rmt2) (OP=WEOF,
Error Number=110, CC=0, KEY=03, ASC=09, ASCQ=00,
SENSE=F0.00.03.00.00.00.04.58.00.00.00.00.09.00.FE.0A.3-
1.18.50.00.00.03.01.31.08.0A.42.48.22.80.10.00.10.35.42-
.12.01.33.12.00.80.33.54.80.06.00.00.00.00.04.00.00.00.-
00.00.00.00.80.00.00.00.00.00.00.01.00.00.00.3C.00.20.0-
0.32.32.45.20.20.20.20.00.A0.00.4B.F0.F1.F0.F2.F5.F1.00-
.00.00.00.00.00.00, Description=An undetermined error has
occurred). Refer to Appendix D in the 'Messages' manual for recommended
action.
07/11/02 17:31:44 ANR8806E Could not write volume label 010251 on the tape
in library LIB3494.
07/11/02 17:34:09 ANR8802E LABEL LIBVOLUME process 16 for library LIB3494
failed.
07/11/02 17:34:09 ANR0985I Process 16 for LABEL LIBVOLUME running in the
BACKGROUND completed with completion state FAILURE at 17:34:09.

KEY=03 means: medium error
ASC=09 and ASCQ=00 mean: "Track following error".

Does this mean that the new cartridge is defect as well?

Kind regards
Thomas Rupp
Vorarlberger Illwerke AG
MAIL:   thomas.rupp AT illwerke DOT at
TEL:    ++43/5574/4991-251
FAX:    ++43/5574/4991-820-8251



------------------------------------------------------------------------------------------