Re: ANR8359E ANR8830E
2001-04-23 16:04:53
Subject: |
Re: ANR8359E ANR8830E |
From: |
Michael Oski <moski AT APPLE DOT COM> |
Date: |
Mon, 23 Apr 2001 12:51:55 -0700 |
I've got a dozen or so 3494 Libraries with 2 to 5 3590 E1A's per silo. I
typically run into these errors a few times per week on a regular basis.
I've also had the micro code upgraded, and had *many* hardware
replacements/adjustments performed. At this point, the only thing to do
is track the errors day to day - if the same tape acts up on multiple
drives, we toss the tape - if the same drive acts up on multiple tapes
that don't show problems in other drives, we have the drive serviced
again and again.
On Monday, April 23, 2001, at 12:27 PM, Debbie Lane wrote:
We have been receiving an abnormal amount of ANR8359E Media Fault, and
ANR8830E Excessive media failures for volume.
Hardware has replaced the cleaning brush, tape head, and card pack. ]
ADSM Server - 3.1.2.90
OS - AIX 4.3.3
Atape 6.0.4.0
atldd 4.1.5.0
Tape Library IBM 3494
Tape drive IBM 3590 E1A
Tape brand - IBM
Our CE said we are current on micro code for the library and drives.
Anyone else experiencing this problem?
|
|
|