Date: Wed, 28 Feb 2001 10:54:44 -0500
You need to use the: cancel restore 
command to cancel restartable restores.


David B. Longo
System Administrator
Health First, Inc.
3300 Fiske Blvd.
Rockledge, FL 32955-4305
PH      321.434.5536
Pager  321.634.8230
Fax:    321.434.5525
david.longo AT health-first DOT org


>>> shekhar.dhotre.b AT BAYER DOT COM 02/28/01 10:29AM >>>
  Hi all ,
    I am getting following errors in actlog ..  although no restores in 
progress ..
I rtstored  NT system yestreday .

tsm: TSM>q ses

  Sess Comm.  Sess     Wait   Bytes   Bytes Sess  Platform Client Name
Number Method State    Time    Sent   Recvd Type
------ ------ ------ ------ ------- ------- ----- -------- --------------------
----
     1 Tcp/Ip Run      0 S      478     179 Admin AIX      ADMIN
     1 Tcp/Ip Run      0 S      478     179 Admin AIX      ADMIN

tsm: TSM>q restore

  Sess    Restore        Elapsed    Node Name                    Filespace
Number    State          Minutes                                 Name
------    -----------    -------    -------------------------    -----------
-
    -2    Restartable      1,372    MEDNTTEST                    \\mednttes    
-2    Restartable      1,372    MEDNTTEST                    \\mednttes-
                                                                  t\d$
                                                                  t\d$
    -3    Restartable      1,372    MEDNTTEST                    \\mednttes-
                                                                  t\c$
                                                                  t\c$



ANR1040I Space reclamation started for volume MED252, storage pool COPYPOOL
(process number 6).
ANR1040I Space reclamation started for volume 000064, storage pool COPYPOOL
(process number 6).
ANR1040I Space reclamation started for volume MED503, storage pool COPYPOOL
(process number 6).
ANR1044I Removable volume MED231 is required for space reclamation.
ANR8324I DLT volume MED231 is expected to be mounted (R/W).
ANR1171W Unable to move files associated with node MEDNTTEST, filespace
\\mednttest\d$ on volume MED231 due to restore in progress.
ANR1171W Unable to move files associated with node MEDNTTEST, filespace
\\mednttest\c$ on volume MED231 due to restore in progress.
ANR1171W Unable to move files associated with node MEDNTTEST, filespace
\\mednttest\d$ on volume MED231 due to restore in progress.
ANR1171W Unable to move files associated with node MEDNTTEST, filespace
\\mednttest\c$ on volume MED231 due to restore in progress.
ANR1171W Unable to move files associated with node MEDNTTEST, filespace
\\mednttest\d$ on volume MED231 due to restore in progress.
ANR1171W Unable to move files associated with node MEDNTTEST, filespace
\\mednttest\c$ on volume MED231 due to restore in progress.
ANR0985I Process 6 for SPACE RECLAMATION running in the BACKGROUND completed
with completion state FAILURE at 10:07:16.
ANR1089W Space reclamation terminated for volume MED311 - lock conflict.



"MMS <health-first.org>" made the following
 annotations on 02/28/01 11:00:26
------------------------------------------------------------------------------
This message is for the named person's use only.  It may contain confidential, 
proprietary, or legally privileged information.  No confidentiality or 
privilege is waived or lost by any mistransmission.  If you receive this 
message in error, please immediately delete it and all copies of it from your 
system, destroy any hard copies of it, and notify the sender.  You must not, 
directly or indirectly, use, disclose, distribute, print, or copy any part of 
this message if you are not the intended recipient.  Health First reserves the 
right to monitor all e-mail communications through its networks.  Any views or 
opinions expressed in this message are solely those of the individual sender, 
except (1) where the message states such views or opinions are on behalf of a 
particular entity;  and (2) the sender is authorized by the entity to give such 
views or opinions.
This message is for the named person's use only.  It may contain confidential, 
proprietary, or legally privileged information.  No confidentiality or 
privilege is waived or lost by any mistransmission.  If you receive this 
message in error, please immediately delete it and all copies of it from your 
system, destroy any hard copies of it, and notify the sender.  You must not, 
directly or indirectly, use, disclose, distribute, print, or copy any part of 
this message if you are not the intended recipient.  Health First reserves the 
right to monitor all e-mail communications through its networks.  Any views or 
opinions expressed in this message are solely those of the individual sender, 
except (1) where the message states such views or opinions are on behalf of a 
particular entity;  and (2) the sender is authorized by the entity to give such 
views or opinions.

 ===========================================================================
<Prev in Thread] Current Thread [Next in Thread>