Re: ANR8310E
2000-04-24 07:39:07
ANR8310E An I/O error occurred while accessing library library name.
Explanation: An I/O error occurs while accessing the designated library.
System Action: The operation fails.
User Response: Ensure that the DEVICE parameter associated with the library
is identified correctly in the DEFINE LIBRARY command, and that the library
is currently powered on and ready. If the library has an access door, make
sure it is closed. After checking and correcting these potential problems,
retry the operation.
Also check to make sure the drives are available for the tape to mount. If
processes are running and tapes are taking up the drives you won't be able
to checkin the tape until you dismount the idle volume. Do a "q mount"
command and check for an IDLE tape and use command "dismount volume xxx". I
hope this helps.
Kye Burns
Data Systems Operator Phone: (619) 938-7905
First American CREDCO Fax: (619)) 938-7596
12395 First American Way email: krburns AT firstam DOT com
Poway, CA 92064
> ----------
> From: Taketoshi Ide[SMTP:ide AT CCUEC.UNICAMP DOT BR]
> Reply To: ADSM: Dist Stor Manager
> Sent: Sunday, April 23, 2000 7:14 AM
> To: ADSM-L AT VM.MARIST DOT EDU
> Subject: ANR8310E
>
> Hi
> During running CHECKIN LIBV LIB3590 ADS100 STATUS=PRIVATE , when we
> needed a new
> private volume in a 3590 stack , we got messages ;
>
> ANR8422I CHECKIN LIBVOLUME: Operation for library LIB3590 started as
> process 701.
> ANR8314E Library LIB3590 is full.
> ANR8310E An I/O error occurred while accessing library LIB3590.
> ANR8426E CHECKIN LIBVOLUME for volume ADSM08 in library LIB3590 failed.
>
> I issued a CHECKOUT LIBVOLUME command to make room in the library.
> Can anybod help ?
> Many thanks in advance .
>
> Ide
>
|
|
|