ADSM-L

Re: Error defining 3590 library

2000-02-03 18:15:30
Subject: Re: Error defining 3590 library
From: Bill Smoldt <smoldt AT STORSOL DOT COM>
Date: Thu, 3 Feb 2000 16:15:30 -0700
Tony meant to say index.storsys.ibm.com.  you'll find the Atape driver under
the devdrvr/AIX directory.

You should also pick up a copy of the IBM_scsi_tape_IUG while you're there.

Bill Smoldt    SSSI
Storage Solutions Specialists, Inc.



 -----Original Message-----
From:   ADSM: Dist Stor Manager [mailto:ADSM-L AT VM.MARIST DOT EDU]  On Behalf 
Of
Tony Rynan
Sent:   Thursday, February 03, 2000 1:49 PM
To:     ADSM-L AT VM.MARIST DOT EDU
Subject:        Re: Error defining 3590 library

Hi Marc,

Did you install the Atape driver ???

 Basically AIX will see the device as an "Other SCSI tape device" and not
as a Magstar tape device.
 Install the drivers and "rmdev -dl rmt?" and then run "cfgmgr -v". You can
get the latest drivers from
storsys.index.ibm.com.

The "define drive" command looks okay.

regards Tonyr

"France, Don (Pace)" <don.france-eds AT EDS DOT COM> on 04/02/2000 04:56:32

Please respond to "ADSM: Dist Stor Manager" <ADSM-L AT VM.MARIST DOT EDU>

To:   ADSM-L AT VM.MARIST DOT EDU
cc:    (bcc: Tony Rynan/Australia/IBM)
Subject:  Re: Error defining 3590 library




Check SMITTY and talk with your CE --- maybe look up and decode the error
data;  you may need to redefine the devices to AIX, make sure your AIX
drivers are installed, run cfgmgr (rather than manually defining devices to
AIX), then delete and re-do DEFINEs (LIBR and DRIVE) to TSM.  If smitty
hangs, you gotta reboot the machine --- that can happen if someone's been
popping serial cables/options while the system is running.

Regards,
Don

Don France

Technical Architect, P.A.C.E.
San Jose, CA
mailto:dfrance AT pacbell DOT net
PACE - http://www.pacepros.com
Bus-Ph:   (408) 257-3037




> -----Original Message-----
> From: Marc Layne [mailto:mlayne AT FARITEC.CO DOT ZA]
> Sent: Thursday, February 03, 2000 5:14 AM
> To: ADSM-L AT VM.MARIST DOT EDU
> Subject: Error defining 3590 library
>
>
> Hi all
> I am getting the following error when trying to define an
> 3590 automated
> (SCSI) library. I have checked the system cansee the device
> (/dev/rmtx)
> and i am able to tar to the devices so no problem there.
> Versions: TSM 3.7.0
> AIX version 4.3.2
> Tape : 3590 B11
> Has anyone seen this before...
> All help greatly appreciated....
>
>
> Date/Time             Message
>
> --------------------
> ----------------------------------------------------------
> 020300 12:12:18       ANR8300E I/O error on library 3590LIB1
> (OP=00006C06,
>                        CC=207, KEY=FF, ASC=FF, ASCQ=FF,
> SENSE=**NONE**,
>
>                        Description=Device is not in a state capable of
>
>                        performing request).  Refer to
> Appendix B in the
>
>                        'Messages' manual for recommended action.
>
> 020300 12:12:18       ANR8418E DEFINE LIBRARY: An I/O error occurred
> while
>                        accessing library 3590LIB1.
>
> 020300 12:16:18       ANR8300E I/O error on library 3590LIB1
> (OP=00006C06,
>                        CC=207, KEY=FF, ASC=FF, ASCQ=FF,
> SENSE=**NONE**,
>
>                        Description=Device is not in a state capable of
>
>                        performing request).  Refer to
> Appendix B in the
>
>                        'Messages' manual for recommended action.
>
> 020300 12:16:18       ANR8418E DEFINE LIBRARY: An I/O error occurred
> while
>                        accessing library 3590LIB1.
>
> 020300 13:11:33       ANR8300E I/O error on library 3590LIB1
> (OP=00006C06,
>                        CC=207, KEY=FF, ASC=FF, ASCQ=FF,
> SENSE=**NONE**,
>
>                        Description=Device is not in a state capable of
>
>                        performing request).  Refer to
> Appendix B in the
>
>                        'Messages' manual for recommended action.
>
> 020300 13:11:33       ANR8418E DEFINE LIBRARY: An I/O error occurred
> while
>                        accessing library 3590LIB1.
>
> 020300 13:11:51       ANR2017I Administrator ADMIN issued
> command: QUERY
> ACTLOG
>                        s=error
>
>
>
> Marc Anthony Layne
>
> RS/6000 Product Manager
> Faritec (Pty) Ltd.
> Mail to: mlayne AT faritec.co DOT za
> Tel: +27 21 7629702     Mobile: +27 82 4169086
> Fax: +27 21 7629737
> "You only live once..  but if you do it right once is enough...."
>