ADSM-L

Automated tape error

1999-02-08 11:42:58
Subject: Automated tape error
From: Marco Ventura <Marco.Ventura AT INRANGE DOT COM>
Date: Mon, 8 Feb 1999 11:42:58 -0500
When I configure an ADIC SCALAR 1000 automated scsi tape library to ADSM, I get
the following error.

ANR2017I Administrator ADMIN issued command: DEFINE LIBR
                      adic libt=scsi devi=lb6.0.0.0
ANR8300E I/O error on library ADIC (OP=8401C050, CC=207,
                      KEY=05, ASC=24, ASCQ=00,
                      SENSE=F0.00.05.00.00.00.00.0A.00.00.00.00.24.00.00.C0.00-
                      .07., Description=Device is not in a state capable of
                      performing request).  Refer to Appendix B in the
                      'Messages' manual for recommended action.
ANR8418E DEFINE LIBRARY: An I/O error occurred while
                      accessing library ADIC.
ANR2017I Administrator ADMIN issued command: ROLLBACK

This is with Server revision level 3.1.2.0 and 3.1.2.13.

But it works with ADSM at revision level 3.1.1.3 the library works fine.

Thanks
Marco
<Prev in Thread] Current Thread [Next in Thread>