ADSM-L

[no subject]

2015-10-04 17:50:03
Hi Hadailton,

You should define two libraries:

one is that you have

other is something like:
      def library=manual libtype=manual
      def drive manual mtape device=/your device/

Then when you want to use the drive as a manual library you type:
     update devclass YOURCLASS library=manual

And to change back:
     update devclass YOURCLASS library=THEOLDONE


Hope that help


Osvaldo

Hadailton Carvalho wrote:

> Dear ADSMers,
>
> I have an ADSM server 2 and just one tape drive (3590-B11).
>
> The 3590-B11 supports several kinds of operation: random, manual,
> automatic, etc.
>
> Since the installation date (about 10 months ago), I am using this
> unit as an automated library with 10 cartridges.
>
> But now, 10 cartridges aren't enough to store all data from my
> nodes, so I intend to change the operation mode to manual in
> order to turn easier the mount operation (without checkout-
> checkin).
>
> How can I change a library from automated to manual without
> losing the data that are in the cartridges ?
>
> Thanks for any help.
>
> Hadailton Carvalho.
> Brazil.