Hi friends,
ADSM Server:
MVS OpenEdition 5.2.2 (ADSM Version 2, Release 1, Level
0.13/0.13)
ADSM Clients:
WinNT-95-98 -AIX - OS/2
=====================================
During back up process (by TCP/IP),
I'm receiving the msg (see MVS log):
.
. .
ANR5321I End of
volume reached for HC0318 on device 2501.
ANR5208I Dismounting
volume HC0318 (updated).
IEF234E K
2501,HC0318,PVT,ADSM,ADSM
*IEC501A M 2501,PRIVAT,SL,COMP,ADSM,ADSM,ADSM.BFS
IEC705I TAPE
ON 2501,HC0323,SL,COMP,ADSM,ADSM,ADSM.BFS
ANR5323I Assigning
volume HC0323 to SCRTCH.
IEC271I MESSAGE
DISPLAY 'HC0323' ON 2501 ISSUED BY JOB ADSM
*ANR5335E Volume
HC0323 already used.
<<<?????>>>
ANR5208I Dismounting
volume HC0323 (updated).
IEF234E K
2501,HC0323,PVT,ADSM,ADSM
*IEC501A M 2501,PRIVAT,SL,COMP,ADSM,ADSM,ADSM.BFS
IEC705I TAPE
ON 2501,HC0333,SL,COMP,ADSM,ADSM,ADSM.BFS
ANR5323I Assigning
volume HC0333 to SCRTCH.
IEC271I MESSAGE
DISPLAY 'HC0333' ON 2501 ISSUED BY JOB ADSM
ANR1340I Scratch
volume HC0333 is now defined in storage pool BACKTAPE.
.
. .
ANR5217I Dismounting
volume HC0333 - 3 minute mount retention expired.
ANR5208I Dismounting
volume HC0333 (updated).
IEF234E K
2501,HC0333,PVT,ADSM,ADSM
.
. .
This is happening with some cartridges.
In the RACF, these cartridges are free
to R/W.
This message is not available in the
ADSM V2 Messages (SH35-0133-02) or CD.
Thanks so much for your help,
Floriano
=======
--------------2B3DF7011439717046DEFCE0--
=========================================================================
|