Re: 3494 errors on aix 4.2.1 - adsm ver 3.1.1.5
1998-08-19 14:56:14
Subject: |
Re: 3494 errors on aix 4.2.1 - adsm ver 3.1.1.5 |
From: |
Tom Bell <tom.bell AT WAII DOT COM> |
Date: |
Wed, 19 Aug 1998 13:56:14 -0500 |
When we've seen these errors, it has been because the 3494's barcode
reader has failed. There is a known problem with the ribbon cable
connecting the reader to the gripper base, such that after a large
number of gripper rotations the ribbon cable cracks near the connector
on the reader end. We've had this happen several times on our 3 year
old 3494. There should be detailed entries in the 3494's error and
transaction logs that identify the problem more clearly (at least to an
IBM CE).
>
> Anybody ever see this before - I just checked in some new tapes last
> week and now these errors are showing up in my AIX errlog -
>
> Does this mean that the 3494 library cant read the volser barcode on the
> tape?
>
> ts40@spf2n9sw:/home/home1/ts40 $ errpt -a | more
> ------------------------------------------------------------------------
> ---
> LABEL: SYSLOG
> IDENTIFIER: C6ACA566
>
> Date/Time: Wed Aug 19 00:10:33
> Sequence Number: 7644
> Machine Id: 000066218900
> Node Id: spf2n9sw
> Class: S
> Type: UNKN
> Resource Name: lmcpd
>
> Description
> MESSAGE REDIRECTED FROM SYSLOG
>
> User Causes
> OPERATOR REDIRECTED SYSLOG MESSAGES TO ERROR LOG
>
> Recommended Actions
> REVIEW DETAILED DATA
>
> Detail Data
> SYSLOG MESSAGE
> ERROR on adsm3494, volume SP0152, ERA 6F Library Vision Failure
> ------------------------------------------------------------------------
> ---
--
Tom Bell tom.bell AT wg.waii DOT com
Tom Bell tom.bell AT wg.waii DOT com
Western Geophysical office: (713) 689-2203
10001 Richmond, Room 3705 pager: (713) 415-0419
Houston, TX 77042
|
|
|