Hi ADSMer,
Whenever there is a power outage, our 3494 library's database will
be corrupted. I am thinking of shutting down the 3494 controller which
run on OS/2 via APC powerchute plus software but not sure is there any
REXX or DOS script there shutdown both the database and OS
gracefully. Powerchute is capable of issuing a command after power
outage is detected. Any help would be greatly appreciated.
Regards,
How Cheong
onghc AT singnet.com DOT sg
|